Trials / Completed
CompletedNCT01791712
Efficacy of Online Hemodiafiltrationlysis in Cytokine Removal
Enhanced Vascular Endothelial Growth Factor and Pro-inflammatory Cytokine Clearances With On-line Hemodiafiltration Versus High-flux Hemodialysis in Sepsis-related Acute Kidney Injury Patients
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 28 (actual)
- Sponsor
- Chulalongkorn University · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
Following the concept of "peak concentration hypothesis", which suggest the cutting peak of pro- and anti-inflammatory mediators would result in restoring a situation of immunohomeostasis. The investigators conducted the prospective randomized controlled trial aimed to compare the clearance efficacy between on-line hemodiafiltration and high-flux hemodialysis in sepsis-related acute kidney injury patients. The lowering cytokines level during sepsis is postulated to improved outcomes in sepsis.
Detailed description
1. Blood samples were taken from patients before and at the end of 4-hour in the first dialysis session. The percentage of reductions were calculated from the before and ending samples. The values of postfilter samples were corrected for changes in plasma volume, based on hemoglobin (Hb) of prefilter. 2. VEGF and other cytokines (IL-6, IL-8, IL-10, and TNF-α) were determined in the plasma separated from EDTA blood. After collection, plasma separation was achieved by centrifugation for 10 min at 1,500 g. Immediately after separation, the samples were stored at -70 ºC until further analysis. 3. All determinations were carried out in duplicate. The panels of cytokines (VEGF, IL-6, IL-8, IL-10, and TNF-α) were measured using the Luminex xMap-based multiplex technology. Assays were performed using the MILLIPLEX MAP (multi-analyte panels) 5-plex Cytokine Kit (Millipore, Billerica, MA) on the Luminex® instrument according to the manufacturer's procedure.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | On-line hemodiafiltration | pre-dilution 40% of blood flow rate blood flow rate 300-350 ml/min dialysate flow rate 800 ml/min |
| PROCEDURE | High-flux Hemodialysis | blood flow rate 300-350 ml/min dialysate flow rate 800 ml/min |
Timeline
- Start date
- 2010-01-01
- Primary completion
- 2011-10-01
- Completion
- 2011-10-01
- First posted
- 2013-02-15
- Last updated
- 2013-02-15
Locations
1 site across 1 country: Thailand
Source: ClinicalTrials.gov record NCT01791712. Inclusion in this directory is not an endorsement.