Clinical Trials Directory

Trials / Completed

CompletedNCT01681719

Ergospirometric Values and WBV in Elderly

Whole Body Vibration as Alternative for Improve the Ergospirometric Values in Elderly: a Randomized Clinical Trial

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
25 (actual)
Sponsor
Maíra F Pessoa · Academic / Other
Sex
All
Age
60 Years – 74 Years
Healthy volunteers
Accepted

Summary

this study aims evaluate the ergospirometric values after 03 months of training with WBV in elderly health people. The hypothesis is increases of ergospirometric values.

Conditions

Interventions

TypeNameDescription
DEVICEWBV and Resistanceuse of WBV and resistance device during 03 months in elderly health people. The WBV used progressive increases of time and amplitude and the resistance training improves the weight. For Resistance: performed in upper and lower limbs in weight machine Mega II Movement®, used guidelines from American College of Sports Medicine for elderly, with two series of 08 repetitions (75% weight of one RM), considered for RM calculation the maximum voluntary isometric contraction. For WBV: used MY3 platform (Power Plate®, MY3, UK) frequency 35 hertz, tri-axial, amplitude 02 mm in adaptation and initial phases, increasing to 04 mm in phases intermediate and final. The time initial was 10 minutes, progressed to 15 min in second month, concluding with 20 min. Rest time between series remained 01 min.
DEVICEresistance & sham WBVused only resistance For Resistance: performed in upper and lower limbs in weight machine Mega II Movement®, used guidelines from American College of Sports Medicine for elderly, with two series of 08 repetitions (75% weight of one RM), considered for RM calculation the maximum voluntary isometric contraction. For WBV: used MY3 platform (Power Plate®, MY3, UK)off.
DEVICEWBV & resistance shamused really the WBV, but sham for resistance training For Resistance: performed similar movments in upper and lower limbs in weight machine Mega II Movement®, without using weights. For WBV: used MY3 platform (Power Plate®, MY3, UK) frequency 35 hertz, tri-axial, amplitude 02 mm in adaptation and initial phases, increasing to 04 mm in phases intermediate and final. The time initial was 10 minutes, progressed to 15 min in second month, concluding with 20 min. Rest time between series remained 01 min.

Timeline

Start date
2011-01-01
Primary completion
2011-12-01
First posted
2012-09-10
Last updated
2012-09-10

Locations

1 site across 1 country: Brazil

Source: ClinicalTrials.gov record NCT01681719. Inclusion in this directory is not an endorsement.