CompletedNCT01575353

Nasal High-flow Versus Venturi Mask Oxygen Therapy in the Post-extubation Period

Nasal High-flow Oxygen Therapy vs Standard Oxygen Therapy Via Venturi Mask in the Post-extubation Period

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
105 (actual)
Sponsor
Catholic University of the Sacred Heart · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The aim of the study is to compare two devices for oxygen therapy, nasal high-flow and Venturi mask, in critically ill patients in the post-extubation period. The hypothesis is that nasal high-flow may be superior to the Venturi mask in terms of oxygenation

Detailed description

Acute respiratory failure is one the most common reason for admission and mechanical ventilation is the most frequent procedure performed in the intensive care unit (ICU). After extubation, oxygen therapy is commonly used to correct residual impairment in oxygenation. Oxygen therapy is usually performed via a Venturi mask allowing to deliver predetermined oxygen concentrations. The face mask is used in the place of nasal cannula in part because patients with acute respiratory failure (ARF) breath preferentially through an open mouth rather than the nose. The mask may, however, reduce comfort and patients with ARF, who are often agitated and poorly cooperative, may displace or self-remove the mask. Given that oxygen delivered to the patient is dry, clinical practice guidelines recommend humidifying the oxygen when above 4 l/min in the ICU setting, because the humidification function of the nasal mucosa can be insufficient at high oxygen flow rates and/or the critically ill patient with ARF often breathes through the mouth. Breathing dry oxygen could provoke dryness of the mouth, nose, throat and respiratory tract, resulting in discomfort and pain that are frequent in the ICU setting. Breathing dry air by the nose may also lead to the alteration of the mucociliary transport system and cause an increase of airway resistance in healthy subjects. However, there are no recommendations concerning the type of humidification device to use. High-flow oxygen therapy is commonly practiced in the ICU. Recently, a method was described in which high-flow oxygen is delivered through a nasal cannula with an active humidification system that optimizes oxygen administration in patients with ARF (Optiflow, Fisher \& Paykel, New Zealand). This system has several theoretical advantages. The delivery of high flows decreases dilution of the inhaled oxygen and, by matching patient's peak flow, allows accurate delivery of the set FiO2 throughout the whole inspiratory phase. In addition, a flow-dependent effect of continuous positive airway pressure, possibly due to an air entrainment mechanism, has been documented in healthy volunteers and in patients with COPD. Lastly, the use of high humidity levels may prevent damage to the ciliated epithelium of the airways, maintain mucociliary system activity, and facilitate the elimination of secretions. Through these effects, this new device for high-flow oxygen therapy has the potential to be effective and to improve tolerance to the treatment more than conventional systems for oxygen therapy, such as the Venturi mask. In the present randomized, controlled trial, the investigators will compare two devices for oxygen therapy, nasal high-flow oxygen therapy and the standard Venturi mask, in critically ill patients who need oxygen in the post-extubation period. The hypothesis is that nasal high-flow is superior to the Venturi mask in terms of oxygenation

Conditions

Interventions

TypeNameDescription
DEVICEVenturi maskThe patients will receive oxygen delivered through a conventional Venturi mask. The FiO2 (color coded) will be adjusted in order to obtain a SpO2 between 92% and 98% in hypoxemic patients and between 88% and 95% in hypercapnic patients.
DEVICENasal high-flowThe patients will receive oxygen delivered through the nasal high-flow system (Optiflow™). The FiO2 will be adjusted in order to obtain a SpO2 between 92% and 98% in hypoxemic patients and between 88% and 95% in hypercapnic patients. Gas flow will be set at 50l/min.

Timeline

Start date
2010-12-01
Primary completion
2011-05-01
Completion
2011-11-01
First posted
2012-04-11
Last updated
2014-02-28

Locations

2 sites across 1 country: Italy