Clinical Trials Directory

Trials / Completed

CompletedNCT01528878

Safety, Efficacy, and Dosing of Stereotactic Radiosurgery for Hepato-cellular Carc/Colo-rectal Liver Metastases

A Dose-finding, Safety and Preliminary Efficacy Study of Stereotactic Radiosurgery for Hepato-cellular Carcinoma and Metastatic Disease to the Liver.

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
30 (actual)
Sponsor
UNC Lineberger Comprehensive Cancer Center · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The purpose of this study is to determine a tolerable dose of radiation delivered by the CyberKnife system in two groups of patients with hepatocellular carcinoma (HCC).

Detailed description

The CyberKnife system has been cleared by the U.S. Food and Drug Administration (FDA) to treat lesions, tumors and conditions anywhere in the body when radiation treatment is indicated. In order to treat tumors during the respiratory cycle (vs. increasing the margin of treatment around the tumor to compensate for movement or requiring the patient to breath hold during the delivery of each beam), the Synchrony™ option, a system option that enables dynamic radiosurgery during respiration, will be used. The purpose of this study is to determine a tolerable dose of radiation delivered by the CyberKnife in two groups of patients with hepatocellular carcinoma (HCC).Group 1: Patients with HCC and Childs A cirrhosis, and patients with colorectal liver metastases. Group 2: Patients with Childs B cirrhosis. Patients will be irradiated with radiation doses using the CyberKnife system in 3-5 radiation fractions using guidance from fiducials placed by interventional radiology. Treatments will be delivered with standard CyberKnife procedures to account for respiratory motion and set up variations. The fiducial location will be the prime determinant of the delivery site and respiratory motion and fiducial markers will be placed via percutaneous approach by interventional radiology.

Conditions

Interventions

TypeNameDescription
RADIATIONStereotactic Radiosurgery using the CyberKnife System.Radiation: Stereotactic Radiosurgery using the CyberKnife System. The CyberKnife system has been cleared by the U.S. Food and Drug Administration (FDA) to treat lesions, tumors and conditions, anywhere in the body when radiation treatment is indicated. To address movement of target lesion during the respiratory cycle, the Synchrony™ option will be used. The Synchrony option precisely tracks tumors in or near the target organ as they move, enabling the highly focused beams of radiation to destroy the tumors with minimal injury to adjacent normal tissue. The Synchrony option records the breathing movements of a patient's chest and combines that information with sequential x-ray pictures of tiny markers inserted inside or in the proximity of the tumor to enable precise delivery of radiation during any point in the respiration cycle. The CyberKnife system with the Synchrony option enables reduced normal tissue exposure by using smaller treatment margins and increased accuracy.

Timeline

Start date
2009-04-01
Primary completion
2014-08-18
Completion
2016-01-28
First posted
2012-02-08
Last updated
2018-07-26
Results posted
2018-05-15

Locations

2 sites across 1 country: United States

Source: ClinicalTrials.gov record NCT01528878. Inclusion in this directory is not an endorsement.