Clinical Trials Directory

Trials / Completed

CompletedNCT01108237

Alignment Comparison Between TruMatch™ Personalized Solutions and Conventional Total Knee Replacement Instrumentation

Comparison of In Vivo Alignment With TruMatch™ Personalized Solutions Compared to Conventional Instrumentation in Total Knee Replacement (TKR)

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
78 (actual)
Sponsor
DePuy Orthopaedics · Industry
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Not accepted

Summary

This investigation is intended to provide clinical information about alignment using TruMatch™ and to compare the results to a conventional total knee replacement. TruMatch™ will be compared to a historical control study, which compares alignment results of computer aided surgery (CAS) and conventional surgical techniques. The purpose of this investigation is to determine whether TruMatch™ alignment is non-inferior to alignment achieved with conventional instrumentation. This investigation will compare long leg alignment in total knee replacement achieved by the two types of procedures. Radiographic analysis will be performed by the same independent radiographic reviewer as the historical control study.

Detailed description

The study is designed as a prospective, multi-center, non-randomized, clinical investigation to determine whether TruMatch™ alignment is non-inferior to alignment achieved in a recently completed study (historical control) with conventional instrumentation. Each enrolled Subject will undergo a total knee replacement using the TruMatch™ surgical technique. This investigation will require the Subject to be followed once postoperatively to collect radiographs. Follow-up will occur typically 2 to 12 weeks after surgery and when the Subject can achieve full leg extension (+/-5 degrees) and can tolerate weight-bearing.

Conditions

Interventions

TypeNameDescription
OTHERTruMatch™ Personalized SolutionsTruMatch™ Personalized Solutions is the brand name of DePuy Orthopaedics, Inc. custom patient instrumentation. TruMatch™ is a pair of custom-made cutting blocks that allow distal femoral and proximal tibial cuts to be made according to a predefined surgical plan. The inner surface of the femoral block is manufactured to match the geometry of the patient's distal femur. The inner surface of the tibial block is manufactured to match the patient's proximal tibia. The geometric data is obtained from a CT scan and a preoperative plan approved by the surgeon.
DEVICETotal Knee Arthroplasty with Conventional Instrumentation.Total Knee Arthroplasty (PFC Sigma System) implanted using conventional instruments, not TruMatch™ instrumentation.

Timeline

Start date
2009-10-01
Primary completion
2011-03-01
Completion
2011-03-01
First posted
2010-04-21
Last updated
2023-10-24
Results posted
2012-05-21

Locations

4 sites across 1 country: United States

Source: ClinicalTrials.gov record NCT01108237. Inclusion in this directory is not an endorsement.