Clinical Trials Directory

Trials / Unknown

UnknownNCT00876551

Endoscopic-vacuum Assisted Closure of Intrathoracic Postsurgical Leaks

Endoscopic - Vacuum Assisted Closure of Intrathoracic Postsurgical Leaks

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
30 (estimated)
Sponsor
Hannover Medical School · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The purpose of this study is to determine the short and long term outcome of endoscopic vacuum assisted closure of intrathoracic postsurgical leaks.

Detailed description

Intrathoracic leakage is a serious complication after esophageal surgery. The reported incidence of esophageal anastomotic leaks after gastrectomy and esophagectomy ranges from 5% to almost 30%. Within the last 10 years endoscopic treatment has changed the approach to intrathoracic anastomotic leakages. Application of metal clips, injection of fibrin glue and placement of self expanding metal or plastic stents (SEMS/SEPS) have been reported to successfully achieve closure of postoperative anastomotic leaks in approximately 66-100%. Alternative endoscopically treatment modalities are welcome especially in cases of failure of the above mentioned endoscopic treatment modalities to prevent the necessity of surgical reintervention which is associated with high mortality or mutilating surgical outcome such as proximal diversion with cervical esophagostomy. Vacuum-assisted closure (V.A.C.) is an established treatment modality for extensive cutaneous infected wounds. The V.A.C. system device is based on a negative pressure applied to the wound via a vacuum sealed sponge tissue. The sponge results in formation of granulation tissue, while the vacuum removes wound secretions and reduces edema and therefore improves blood flow, all together achieving consecutive wound closure. Since its introduction in the late 1990´s the number of indications for the V.A.C. system has steadily increased. Recently the endoluminal application of a vacuum assisted wound closure system for the closure of rectal anastomotic fistulas has been reported. Our group reported the successful closure of intrathoracic anastomotic leaks in two cases by endoscopic placement of a vacuum assisted closure system. Here we plan to study the efficacy, safety and long term outcome of E-V.A.C. to treat major intrathoracic postsurgical leaks.

Conditions

Interventions

TypeNameDescription
PROCEDUREEndoscopic vacuum assisted closure1. Endoscopic debridement of wound using a regular biopsy forceps. 2. Introduction via the nose and oral exteriorization of a silicone duodenal tube (Freka Tube, 15 Ch, Fresenius Kabi, Bad Homburg v.d. H. Germany) 3. Fixation of a polyurethane foam (sponge, pore size 400-600 µm, KCI, Wiesbaden Germany) to the tip of the duodenal tube with a mersilene suture (0,35mm, Johnson \& Johnson, St-Stevens-Woluwe, Belgium). 4. Trimming of the sponge to the specific wound size. 5. Endoscopic placement of the sponge in the intrathoracic leak with a grasping forceps (Olympus, Germany) 6. Application of continuous suction of 125mmHg using vacuum pump (KCI, Wiesbaden Germany). 7. Sponge exchange twice a week until wound grounds are clean and closed

Timeline

Start date
2008-01-01
Primary completion
2012-12-01
Completion
2012-12-01
First posted
2009-04-06
Last updated
2010-05-26

Locations

1 site across 1 country: Germany

Source: ClinicalTrials.gov record NCT00876551. Inclusion in this directory is not an endorsement.