Clinical Trials Directory

Trials / Completed

CompletedNCT00788788

Heliox in Experimental Upper Airway Obstruction

PoC Study of Heliox With Helium-Fractions Between 25 and 75% in Experimental Upper Airway Obstruction

Status
Completed
Phase
Phase 1 / Phase 2
Study type
Interventional
Enrollment
44 (actual)
Sponsor
University of Witten/Herdecke · Academic / Other
Sex
All
Age
18 Years – 60 Years
Healthy volunteers
Accepted

Summary

Currently it is common medical wisdom that HELIOX (mixture of Helium in Oxygen) with a fraction of Helium below 60% is not effective in reducing airway obstruction. The investigators test the hypothesis that HELIOX with a fraction of Helium below 60% is still effective in relieving airway obstruction in a double-blind, randomized and controlled clinical PoC study with experimental upper airway obstruction.

Detailed description

HELIOX is a mixture of Helium and Oxygen. It is a therapeutic modality that can improve upper and lower airway obstruction. The lower density of Helium can help to relieve airway obstruction and is known to lower the work of breathing. The fraction of Helium (FHe) in HELIOX should be maximized (e.g. up to a fraction of 79% with 21% of oxygen added) in order to achieve optimal anti-obstructive outcome and according to the literature a FHe below 60% renders HELIOX ineffective. Objective: We conducted an investigator-initiated trial using different mixtures of Helium and Oxygen in 44 healthy volunteers in a randomized and double-blinded fashion. Methods: After an adjustment phase the subjects were breathing through two different external resistors (intratracheal tube with inner diameter of either 4.0mm or 5.0mm) while gas of different composition (medical air with 79% Nitrogen and 21% Oxygen as control gas and HELIOX with a fraction of either 25%, 50% or 75% Helium in Oxygen, respectively) was provided in a blinded and random fashion. A crossover design was used so that every subject was exposed to every HELIOX gas mixture. Subjects were asked to score their degree of dyspnea after breathing different gas mixtures for 2 minutes intervals. In addition the variability of different hemodynamic parameters was assessed (continuous non-invasive blood pressure (systolic, diastolic and mean blood pressure), impedance cardiography (stroke volume and cardiac output), ECG (heart rate variability)) were assessed non-invasively and used to detected a change in the degree of airway obstruction in respect to the added load and the gas mixture.

Conditions

Interventions

TypeNameDescription
DRUGHELIOXHELIOX is a mixture of Helium in Oxygen with a low density and the ability to reduce the work of breathing in subjects with airway obstruction. The fractions of Helium was altered in a different order depending on the arm of the study

Timeline

Start date
2007-11-01
Primary completion
2007-12-01
First posted
2008-11-11
Last updated
2008-11-21

Locations

1 site across 1 country: Germany

Source: ClinicalTrials.gov record NCT00788788. Inclusion in this directory is not an endorsement.