Clinical Trials Directory

Trials / Completed

CompletedNCT00707265

rhBMP-2/CRM/CD HORIZON® Spinal System Pivotal Study

A Prospective, Randomized Clinical Investigation of rhBMP-2 and Compression Resistant Matrix With the CD HORIZON® Spinal System for Posterolateral Lumbar Fusion in Patients With Symptomatic Degenerative Disc Disease

Status
Completed
Phase
Phase 3
Study type
Interventional
Enrollment
463 (actual)
Sponsor
Medtronic Spinal and Biologics · Industry
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The purpose of this study was to evaluate the rhBMP-2/CRM/CD HORIZON® Spinal System as a method of facilitating spinal fusion in patients with degenerative disc disease.

Detailed description

This clinical trial was conducted to evaluate the rhBMP-2/CRM/CD HORIZON® Spinal System for posterolateral fusion treatment of patients with symptomatic degenerative disc disease versus the control group of autogenous bone with the CD HORIZON® Spinal System. The investigational treatment was the open bilateral posterolateral implantation of the rhBMP-2/CRM/CD HORIZON® Spinal System. One investigational implant was placed across two adjacent transverse processes on each side of the spine during the spinal fusion procedure. The control treatment was the bilateral posterolateral implantation of the autogenous bone harvested from the iliac crest with the CD HORIZON® Spinal System.

Conditions

Interventions

TypeNameDescription
DEVICErhBMP-2/CRM/CD HORIZON® Spinal SystemThe rhBMP-2/CRM component of the investigational device consists of recombinant human Bone Morphogenetic Protein-2 (rhBMP-2) and a compression resistant matrix (CRM) carrier consisting of an absorbable collagen sponge imbedded with biphasic calcium phosphate. The posterior spinal fixation system, the CD HORIZON® Spinal System, is a commercially available rod-based spinal system intended for temporary stabilization of the spine in order to facilitate fusion. The CD HORIZON® Spinal System is available in either titanium or stainless steel. For this study, only titanium implant components will be used.
DEVICEAutograft/CD HORIZON® Spinal SystemThe control will be autogenous bone taken from the iliac crest of the patient and placed bilaterally across two adjacent transverse processes and used in conjunction with the CD HORIZON® Spinal System. When used as a posterior spine thoracic/lumbar system, the CD HORIZON® CANNULATED M8 MULTI-AXIAL SCREW components are intended for several indications including degenerative disc disease.

Timeline

Start date
2002-03-01
Primary completion
2005-05-01
Completion
2010-02-01
First posted
2008-06-30
Last updated
2023-05-10

Locations

28 sites across 1 country: United States

Source: ClinicalTrials.gov record NCT00707265. Inclusion in this directory is not an endorsement.