Comparison Of Trabeculectomy Versus The Ex-PRESS Miniature Glaucoma Device In The Same Patient: A Prospective Randomized Study

Prospective, Randomized Clinical Trial,to Compare Standard Trabeculectomy to the Ex-PRESS Mini Glaucoma Shunt Implantation Under a Scleral Flap in Eyes With Open-Angle Glaucoma

Status
Completed
Phase
Phase 4
Study type
Interventional
Enrollment
30 (planned)
Sponsor
University of Witwatersrand, South Africa · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

the purpose of this study was to compare standard trabeculectomy to the Ex-PRESS mini glaucoma shunt implantation under a scleral flap in eyes with open-angle glaucoma.In this report, we describe the results of a prospective, randomized trial in which subjects with bilateral primary open-angle glaucoma underwent the two procedures in fellow eyes.Design: Prospective, randomized clinical trial. Participants: 15 subjects with bilateral primary open-angle glaucoma Methods: Subjects underwent the two procedures in fellow eyes. Safety and efficacy were evaluated for up to two years. Main Outcome Measures: Mean IOP and surgical success rates. Results: Mean IOP was similar in Ex-PRESS and trabeculectomy eyes at all time points except month 9, when Ex-PRESS eyes had lower mean IOP (13.2 mmHg vs 16.5 mmHg, respectively; p=0.025). Percent IOP reduction was also similar at all time points except postoperative day 1, when trabeculectomy eyes were lower (75.5% vs 65.8%, respectively; p=0.003), likely due to a higher rate of early hypotony in trabeculectomy eyes versus Ex-PRESS eyes (47% vs 7%, respectively). Complete (without medications) and qualified (with or without medications) successes were more common at all IOP cut-off values in Ex-PRESS eyes than trabeculectomy eyes at last visit (p=0.015, p=0.015 respectively). Postoperative complications were uncommon in both groups, but trabeculectomy eyes required more postoperative interventions than Ex-PRESS eyes.

Conditions

Interventions

TypeNameDescription
DEVICEEx-PRESS implantationI. Mobility check of the device. II. Administration of a local or topical anesthetic. III. Preparation and coverage of the eye by conventional sterile procedures. IV. Injection of viscoelastic material into the AC through a paracenthesis. V. Creation of a scleral tunnel up to clear cornea. VI. Creation of a (5 mm) conjunctival tunnel fornix based. VII. Lifting of the conjunctiva and tenon. VIII. Formation of a 2mm scleral incision at 0.3mm depth, 1.5mm from the limbus. IX. Application of 0.5µg/ml MMC under the tunnel for one minute. X. Penetration into the AC using a 0.65mm stiletto, inside the tunnel of the sclera-corneal junction. XI. Implantation of the Ex-PRESSTM through that pre-incision at the sclerocorneal junction. XII. Introducer withdrawal. XIII. Tucking the plate under the scleral tunnel, and verification of the position inside the tunnel. XIV. Reposition the conjunctiva with 1 - 2 sutures at the limbus. XV. Closing the conjunctiva with a suture.
PROCEDURETrabeculectomystandard trabeculectomy