Optivol Diagnostic Data for Discharge in Heart Failure
Comparing ICD Device Diagnostics to Hospitalized Heart Failure Patient Symptoms and Physician Opinion on Discharge Readiness
- Status
- Completed
- Phase
- —
- Study type
- Observational
- Enrollment
- 23 (actual)
- Sponsor
- Thomas Jefferson University · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
The objective of this study is to evaluate whether the heart rate variability, daily heart rate, and/or intrathoracic impedance recorded by implantable cardiac devices can be used in conjunction with other traditional clinical practice methods to determine if heart failure patients are ready for hospital discharge.
Detailed description
Implantable cardioverter defibrillator (ICD) devices with or without cardiac resynchronization therapy (CRT-D) have the ability to continuously monitor heart rate variability, daily heart rate, and patient activity. Changes in these measures have been associated with heart failure prognosis. In addition, ICD or CRT-D devices also have the ability to measure daily intrathoracic impedance. Previous data have demonstrated that device-based intrathoracic impedance measurements correlate with pulmonary capillary wedge pressure and fluid retention, both of which are common measures of heart failure status. The objective of this study is to evaluate whether the heart rate variability, daily heart rate, and/or intrathoracic impedance can be used in conjunction with other methods to determine if patients are ready for hospital discharge. This will be the first step in potentially developing an inpatient care strategy which includes implantable device data. It is hypothesized that device diagnostic data will identify an appropriate and safe time to discharge patients admitted for worsening heart failure symptoms before usual clinical indicators. More specifically, we hypothesize that device data will "normalize" at least one day prior to the clinical indicators of readiness for discharge and patients discharged prior to "normalization" of the device data will be at greater risk for rehospitalization
Conditions
Timeline
- Start date
- 2006-12-01
- Primary completion
- 2010-02-01
- Completion
- 2010-02-01
- First posted
- 2007-01-09
- Last updated
- 2010-08-20
Locations
5 sites across 1 country: United States
Source: ClinicalTrials.gov record NCT00420108. Inclusion in this directory is not an endorsement.