Trials / Not Yet Recruiting
Not Yet RecruitingNCT07526415
Effect of Recording Duration on Heart Rate Variability During taVNS
Effect of Recording Duration on Heart Rate Variability During Transcutaneous Auricular Vagus Nerve Stimulation: A Randomized, Sham-Controlled Crossover Study
- Status
- Not Yet Recruiting
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 40 (estimated)
- Sponsor
- Sinop University · Academic / Other
- Sex
- All
- Age
- 18 Years – 40 Years
- Healthy volunteers
- Accepted
Summary
This study aims to evaluate how different heart rate variability (HRV) recording durations reflect autonomic nervous system responses during transcutaneous auricular vagus nerve stimulation (taVNS) in healthy adults. In a randomized, sham-controlled crossover design, participants will attend two separate sessions and receive both active taVNS and sham stimulation in randomized order. During each session, a continuous 10-minute HRV recording will be obtained, and 1-minute, 5-minute, and 10-minute analysis windows will be compared. Blood pressure and pulse will also be measured before and after stimulation. The study will investigate whether shorter or longer HRV recording durations provide results comparable to the standard 5-minute recording and which duration most reliably detects autonomic changes during taVNS.
Detailed description
The vagus nerve plays a central role in autonomic regulation, and heart rate variability (HRV) is a widely used noninvasive marker of autonomic nervous system activity. Transcutaneous auricular vagus nerve stimulation (taVNS) has increasingly been used in experimental and clinical research as a noninvasive method to modulate vagal activity. Although previous studies suggest that taVNS may influence parasympathetic activity, HRV measurement duration remains an important methodological issue. Standard short-term HRV analysis is commonly based on 5-minute recordings, but ultra-short and longer recordings are also used, and their validity during taVNS has not been sufficiently clarified. This study is designed to determine whether different HRV recording durations provide comparable and reliable information during taVNS. The study will use a randomized, sham-controlled crossover design. Healthy adult participants will attend two sessions separated by a washout period of 48 to 72 hours. In one session, participants will receive active taVNS; in the other, they will receive sham stimulation. The order of sessions will be randomized. During each session, HRV data will be collected continuously for 10 minutes using a Polar H10 chest strap. From this single uninterrupted recording, 1-minute, 5-minute, and 10-minute analysis windows will be derived. HRV parameters from time-domain and frequency-domain analyses will be calculated. Blood pressure and pulse will be measured before and after the intervention using an automated upper-arm blood pressure monitor. Active taVNS will be applied to the cymba conchae region of the ear using commonly reported stimulation parameters. Sham stimulation will be delivered with the same device and similar sensory conditions, but at a non-vagal ear location to minimize physiologic vagal effects. This design is intended to control for nonspecific sensory and expectation-related effects. The primary objective is to assess whether the standard 5-minute HRV recording during taVNS detects autonomic effects compared with sham stimulation. Secondary objectives are to examine the agreement between 1-minute, 5-minute, and 10-minute HRV measurements and to evaluate whether shorter or longer recordings provide additional methodological value. The relationship between HRV findings and hemodynamic responses, including blood pressure and pulse, will also be explored. This study may help identify the most appropriate HRV recording duration for future taVNS research and contribute to methodological standardization in this field.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Transcutaneous Auricular Vagus Nerve Stimulation | Active transcutaneous auricular vagus nerve stimulation will be applied bilaterally to the cymba conchae region of the ear using a transcutaneous stimulation device. Stimulation will be delivered for 10 minutes with a frequency of 25 Hz, a pulse width of 200 to 300 microseconds, and an individually adjusted intensity that is clearly perceptible but not painful. Heart rate variability will be recorded continuously during the intervention. |
| DEVICE | Sham Stimulation | Sham stimulation will be delivered for 10 minutes using the same transcutaneous stimulation device and similar stimulation settings as the active intervention, but the stimulation will be applied to a non-vagal ear region, such as the earlobe or helix, to minimize physiologic vagal effects while maintaining similar sensory input. Heart rate variability will be recorded continuously during the intervention. |
Timeline
- Start date
- 2026-05-01
- Primary completion
- 2026-08-31
- Completion
- 2026-09-15
- First posted
- 2026-04-13
- Last updated
- 2026-04-16
Locations
1 site across 1 country: Turkey (Türkiye)
Source: ClinicalTrials.gov record NCT07526415. Inclusion in this directory is not an endorsement.