Clinical Trials Directory

Trials / Recruiting

RecruitingNCT07491198

Effect Of Trendelenburg Position And Pneumoperitoneum On Optic Nerve Sheath Diameter In Robot-Assisted Prostatectomy

Effect of Steep Trendelenburg Position and Pneumoperitoneum on Optic Nerve Sheath Diameter in Robot-Assisted Laparoscopic Radical Prostatectomy: A Prospective Study

Status
Recruiting
Phase
Study type
Observational
Enrollment
50 (estimated)
Sponsor
Ege University · Academic / Other
Sex
Male
Age
18 Years
Healthy volunteers
Not accepted

Summary

This prospective study aims to evaluate the effect of steep Trendelenburg position and pneumoperitoneum on optic nerve sheath diameter in patients undergoing robot-assisted laparoscopic radical prostatectomy and open radical prostatectomy under general anesthesia. Increased intracranial pressure may occur during robotic surgery due to pneumoperitoneum and head-down positioning. Optic nerve sheath diameter measured by ocular ultrasonography is a non-invasive method used to assess intracranial pressure changes. Hemodynamic and respiratory parameters will also be recorded during surgery. The results of this study may help to better understand the physiological effects of surgical position and pneumoperitoneum during prostatectomy procedures.

Detailed description

Robot-assisted laparoscopic radical prostatectomy requires steep Trendelenburg positioning and carbon dioxide pneumoperitoneum to improve the surgical field. These conditions may lead to increased intracranial pressure due to venous congestion and elevated intrathoracic pressure. Optic nerve sheath diameter measurement by ultrasonography is a noninvasive method that can be used to estimate changes in intracranial pressure during surgery. In this prospective study, patients undergoing robot-assisted laparoscopic radical prostatectomy will be compared with patients undergoing open radical prostatectomy. Optic nerve sheath diameter will be measured at predefined time points during surgery using ocular ultrasonography. Hemodynamic parameters, respiratory variables, intra-abdominal pressure, duration of surgery, blood loss, and administered fluids will also be recorded. The aim of this study is to evaluate the effect of pneumoperitoneum and steep Trendelenburg position on optic nerve sheath diameter and to determine the relationship between optic nerve sheath diameter and intraoperative physiological changes.

Conditions

Timeline

Start date
2026-01-05
Primary completion
2026-06-01
Completion
2026-09-01
First posted
2026-03-24
Last updated
2026-03-24

Locations

1 site across 1 country: Turkey (Türkiye)

Source: ClinicalTrials.gov record NCT07491198. Inclusion in this directory is not an endorsement.