Clinical Trials Directory

Trials / Completed

CompletedNCT07458724

Radiation-free Anatomical Direct Imaging Approach for No-fluoroscopy Cardiac Electrode Implantation

Feasibility and Safety of Transthoracic Echocardiography-Guided Permanent Pacemaker Implantation Without Fluoroscopy

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
31 (actual)
Sponsor
Chinese Academy of Medical Sciences, Fuwai Hospital · Academic / Other
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Not accepted

Summary

Permanent pacemaker implantation is traditionally performed under fluoroscopic (X-ray) guidance. Although effective, fluoroscopy exposes patients and medical staff to ionizing radiation. Transthoracic echocardiography (TTE) is a non-invasive ultrasound imaging technique that allows real-time visualization of cardiac structures without radiation exposure. However, its role in guiding permanent pacemaker implantation has not been systematically evaluated. This study aims to assess the feasibility and safety of performing permanent pacemaker implantation under sole TTE guidance. In the first phase, eligible patients will undergo pacemaker implantation guided only by transthoracic echocardiography. In the second phase, outcomes of patients treated with TTE guidance will be compared with matched patients undergoing conventional fluoroscopy-guided implantation. The study will evaluate procedural success, lead positioning accuracy, electrical performance, complication rates, and elimination of radiation exposure. The overall goal is to determine whether a radiation-free imaging strategy can safely replace conventional fluoroscopic guidance in selected patients requiring pacemaker implantation.

Detailed description

Fluoroscopy-guided permanent pacemaker implantation has been the standard imaging strategy for decades. While fluoroscopy provides reliable projection-based visualization of lead advancement, it exposes patients and medical personnel to ionizing radiation and does not allow direct visualization of myocardial tissue contact or early structural complications. Increasing awareness of cumulative radiation exposure has led to the exploration of alternative imaging strategies in structural and electrophysiological interventions. Transthoracic echocardiography (TTE) provides real-time, radiation-free visualization of cardiac chambers, septal structures, valvular anatomy, and the pericardial space. TTE has been successfully applied in selected structural heart procedures; however, its use in guiding permanent pacemaker implantation has not been systematically studied. The principal challenges of TTE-guided pacing include limited visualization of the entire lead shaft, difficulty in assessing three-dimensional orientation, and uncertainty regarding fixation mechanics. With procedural refinements and structured imaging protocols, these limitations may be overcome. This study is designed to evaluate a radiation-free implantation strategy using sole transthoracic echocardiographic guidance. The first component prospectively assesses procedural feasibility and safety in consecutively enrolled patients. The second component compares outcomes of the TTE-guided cohort with a matched cohort undergoing conventional fluoroscopy-guided implantation. The same prospectively enrolled TTE cohort will serve both feasibility assessment and comparative analysis. The central hypothesis is that TTE-guided pacemaker implantation can achieve high procedural success and acceptable electrical performance while eliminating radiation exposure and maintaining safety comparable to conventional fluoroscopic guidance. By leveraging direct septal visualization and continuous structural monitoring, this approach may provide mechanistic advantages in lead positioning accuracy and complication detection. If validated, this strategy could represent an important step toward fully radiation-free electrophysiological and structural cardiac interventions.

Conditions

Interventions

TypeNameDescription
PROCEDUREPermanent Pacemaker ImplantationPermanent pacemaker implantation performed under sole transthoracic echocardiographic (TTE) guidance without the use of fluoroscopy. Venous access, lead advancement, positioning, and fixation are guided by real-time transthoracic imaging. Ventricular leads are positioned at the interventricular septum under direct echocardiographic visualization. In dual-chamber systems, atrial leads are positioned at the atrial septum due to limitations in visualizing the right atrial appendage under transthoracic imaging. Lead position, septal contact, and potential procedural complications (e.g., pericardial effusion, valvular interference) are continuously assessed using multi-plane echocardiographic views. Fluoroscopy is reserved only for bailout situations if adequate lead positioning cannot be achieved under TTE guidance.

Timeline

Start date
2024-09-01
Primary completion
2025-09-01
Completion
2026-02-01
First posted
2026-03-09
Last updated
2026-03-09

Locations

1 site across 1 country: China

Regulatory