Trials / Not Yet Recruiting
Not Yet RecruitingNCT07414771
Safety and Usability of the Inga Catheter for Labor Induction (INGA-MDP)
A Medical Device Pilot Study to Evaluate the Safety and Usability of the Inga Catheter in Labor Induction
- Status
- Not Yet Recruiting
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 30 (estimated)
- Sponsor
- Aalto University · Academic / Other
- Sex
- Female
- Age
- 18 Years – 56 Years
- Healthy volunteers
- Not accepted
Summary
The goal of this clinical study is to evaluate a new mechanical balloon catheter (INGA) used to prepare the cervix for labor induction in pregnant women at term. The study aims to assess the safety, usability, and performance of the INGA catheter when used for cervical ripening before labor. Researchers will also collect feedback from healthcare professionals and participants about the use of the device. Participants are pregnant women at term with a single baby in a head-down position who meet the study eligibility criteria. Participants will: * have the INGA balloon catheter inserted as part of labor induction, * receive standard clinical care according to hospital practice, * provide information about their experience and outcomes related to the device. The results of this study will help determine whether the INGA catheter is safe and suitable for use in cervical ripening during labor induction.
Detailed description
This prospective, single-arm clinical investigation evaluates the safety, usability, performance, and preliminary efficacy of the INGA mechanical cervical ripening balloon catheter when used for induction of labor at term. The study is conducted as a medical device investigation in accordance with the Declaration of Helsinki, ICH-GCP principles, and applicable regulatory and ethical requirements. All participants provide written informed consent prior to participation. Mechanical cervical ripening is an established method for labor induction, particularly in women with an unfavorable cervix. Balloon catheters promote cervical ripening through direct mechanical dilation and stimulation of endogenous prostaglandin release, offering a non-pharmacological alternative to pharmacologic methods. The INGA catheter is a single-use mechanical single-balloon device intended for placement between the fetal membranes and the internal cervical os during a vaginal examination. After insertion, the balloon is filled with sterile saline according to the device instructions for use and maintained under gentle traction. The device may remain in place for up to 24 hours or until spontaneous detachment. Cervical status is assessed prior to catheter insertion and following catheter detachment or removal, and further induction management, including amniotomy and/or oxytocin administration, is performed according to routine clinical practice. Outpatient cervical ripening may be permitted for selected participants based on predefined clinical criteria and local hospital practice. The study enrolls approximately 30-50 pregnant women at ≥37 weeks of gestation with a singleton pregnancy in cephalic presentation and an unfavorable cervix (Bishop score ≤6) for whom induction of labor has been clinically indicated. Both nulliparous and multiparous women may participate. After providing written informed consent and confirmation of eligibility, participants undergo cervical ripening with the INGA catheter as part of standard induction care. The study does not include a comparison group. The study collects clinical data during cervical ripening, labor, and delivery in order to characterize device performance in a real-world hospital setting. In addition to clinical outcomes, the investigation includes structured assessments of user experience. Participating women complete questionnaires regarding pain and overall experience related to catheter placement and retention. Healthcare professionals complete structured usability evaluations addressing ease of insertion, handling characteristics, and overall device performance. Clinical data are collected during cervical ripening, labor, and delivery to characterize device performance in a real-world hospital setting. In addition to clinical outcomes, structured user-reported data are obtained. Participating women complete questionnaires addressing pain and overall experience during catheter placement and retention. Healthcare professionals complete structured evaluations of device usability, ease of insertion, handling characteristics, and overall performance. Safety is assessed throughout cervical ripening and delivery by systematic monitoring and documentation of adverse events and device-related incidents in accordance with regulatory requirements. As an exploratory pilot investigation, the study is intended to generate preliminary clinical data to support further clinical development and future confirmatory studies.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Cervical ripening, labor induction | This study uses the INGA cervical ripening balloon catheter for labor induction, with standardized insertion and saline filling according to device instructions, allowing the balloon to remain in place up to 24 hours. The trial systematically collects data on catheter usability, insertion experience, patient pain, retention time, and delivery outcomes, as well as feedback from both participants and healthcare professionals regarding device performance and usability. Cervical status is evaluated using the Bishop score before and after catheter use. |
Timeline
- Start date
- 2026-04-01
- Primary completion
- 2026-09-30
- Completion
- 2027-03-31
- First posted
- 2026-02-17
- Last updated
- 2026-02-20
Locations
3 sites across 1 country: Finland
Regulatory
- FDA-regulated device study
Source: ClinicalTrials.gov record NCT07414771. Inclusion in this directory is not an endorsement.