Trials / Completed
CompletedNCT07349953
Correlation Between Anthropometric Characteristics and Age-based Formulas for Uncuffed Pediatric Endotracheal Tube
Estimation of Correlation Betweeen Antropometric Characteristics of Children up to 8 Years and Age-based Formulas for Uncuffed Endotracheal Tube in Elective Intubated Children During General Anesthesia
- Status
- Completed
- Phase
- —
- Study type
- Observational
- Enrollment
- 103 (actual)
- Sponsor
- Mother and Child Health Institute of Serbia Dr Vukan Cupic · Academic / Other
- Sex
- All
- Age
- 1 Day – 8 Years
- Healthy volunteers
- Accepted
Summary
The goal of this observational study is to investigate the correlation between anthropometric characteristics, such as finger circumferences, body weight, body height, and body mass index, and age-based formulas for uncuffed tube size in pediatric patients up to 8 years of age.
Detailed description
Patients who met inclusion criteria entered the study. All included patients were premedicated with midazolam 0.1mg/kg IV 30 minutes before general anesthesia. Induction: propofol 2,5mg/kg IV, rocuronium 0,6mg/kg IV, fentanyl 3mcg/kg IV; maintenance: sevoflurane 1vol% - 2vol%, fentanyl 3mcg/kg IV as needed. reversion of neuromuscular block was achieved using sugammadex. Trachea was intubated using direct laryngoscopy. Intubation performed one anesthesiologist with more than 10 years of clinical experience in pediatric anesthesia. Initial choice of endotracheal tube (ET) was based on the size of little finger. Proper position of ET was confirmed with chest auscultation, capnography and capnometry. If placing ET was difficult or air leak was not detected using inspiratory pressure \> 25cmH2O,ET was replaced with 0,5mm smaller one. If there was air leak using inspiratory pressure \< 10 mmHg ET was replaced with 0.5mm bigger one. All children were ventilated using protective strategy. After intubation, measures were made: 1. Finger's circumference was measured with flexible ruler tape (in millimeters). The tape was wrapped around the base of the finger. Circumferences of index finger, middle finger, ring finger and small finger were documented for each hand. 2. Data of body weight, body height and body mass index were taken from patients history. 3. Sizes of used endotracheal tubes were documented. 4. Calculations of ET tube size using age based formulas were made: for children over 2 years ID (mm) = god/4+4 for children under 2 years of age ODcal (mm) = 0,00223x age(days)+4.88
Conditions
Timeline
- Start date
- 2025-07-01
- Primary completion
- 2025-10-01
- Completion
- 2025-10-10
- First posted
- 2026-01-20
- Last updated
- 2026-01-20
Locations
1 site across 1 country: Serbia
Source: ClinicalTrials.gov record NCT07349953. Inclusion in this directory is not an endorsement.