Clinical Trials Directory

Trials / Not Yet Recruiting

Not Yet RecruitingNCT07303972

Effects of Inspiratory vs Expiratory Breath-Hold on Lung Perfusion Measured by EIT Saline Indicator Method: A Self-Controlled Study

Electrical Impedance Tomography Saline Indicator Technique for Assessing Differences in Lung Perfusion Between Inspiratory and Expiratory Breath-Hold Phases: A Prospective Self-Controlled Study

Status
Not Yet Recruiting
Phase
N/A
Study type
Interventional
Enrollment
100 (estimated)
Sponsor
Shanghai Zhongshan Hospital · Academic / Other
Sex
All
Age
18 Years – 65 Years
Healthy volunteers
Accepted

Summary

This study aims to compare lung perfusion distribution between inspiratory breath-hold and expiratory breath-hold phases using the saline indicator method combined with electrical impedance tomography (EIT). A self-controlled crossover design will be used in which each participant undergoes both breath-hold conditions with standardized rapid intravenous saline injections. The primary objective is to evaluate changes in global and regional pulmonary perfusion under different lung volume states. The findings may improve understanding of perfusion redistribution with lung inflation and support optimized ventilatory strategies in clinical practice.

Detailed description

Electrical impedance tomography (EIT) with saline bolus injection is a noninvasive technique capable of generating real-time regional lung perfusion images based on transient impedance changes. Lung perfusion is highly dependent on lung volume, vascular resistance, and gravity, yet quantitative bedside evaluation remains limited. This prospective self-controlled study investigates the differences in lung perfusion between inspiratory breath-hold (near total lung capacity) and expiratory breath-hold (near functional residual capacity). Each participant will undergo two standardized procedures: (1) expiratory breath-hold followed by a rapid intravenous injection of saline, and (2) inspiratory breath-hold followed by the same injection protocol. The order will be randomized. Perfusion images will be reconstructed using time-impedance curves derived from saline indicator dilution. Regional perfusion parameters, including dependent vs nondependent zones and global perfusion distribution, will be compared between the two phases. This study may provide foundational physiological evidence for understanding perfusion redistribution across lung volumes and support the clinical application of EIT in respiratory monitoring, ventilatory management, and rehabilitation in critically ill patients.

Conditions

Interventions

TypeNameDescription
PROCEDUREElectrical Impedance Tomography Saline Indicator ProcedureParticipants undergo continuous electrical impedance tomography (EIT) monitoring with a circumferential electrode belt placed around the thorax. During the procedure, participants perform standardized inspiratory and expiratory breath-hold maneuvers. At each breath-hold phase, a rapid intravenous bolus of sterile saline (10-20 mL) is administered, followed by a saline flush, to generate transient impedance changes for lung perfusion imaging using the saline indicator technique. EIT data are recorded continuously before, during, and after each saline injection. Each participant undergoes both breath-hold conditions and serves as their own control.
DEVICEElectrical Impedance Tomography DeviceAn FDA-cleared electrical impedance tomography (EIT) device is used to noninvasively monitor thoracic impedance changes during the study procedures. The device is used solely for physiological monitoring and image acquisition and is not being evaluated for safety, performance, or a new indication.

Timeline

Start date
2026-01-01
Primary completion
2027-01-01
Completion
2028-01-01
First posted
2025-12-26
Last updated
2025-12-26

Regulatory

Source: ClinicalTrials.gov record NCT07303972. Inclusion in this directory is not an endorsement.