Trials / Completed
CompletedNCT07303309
Effectiveness of High-Voltage PRF for Chronic Lumbosacral Radicular Pain
Effectiveness of High-Voltage Pulsed Radiofrequency for Chronic Lumbosacral Radicular Pain: A Randomized Controlled Trial
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 22 (actual)
- Sponsor
- Hasanuddin University · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
This randomized controlled trial compared high-voltage (60 V) and low-voltage (45 V) pulsed radiofrequency (PRF) for treating chronic lumbosacral radicular pain in adult patients. The study evaluated differences in pain reduction (using the Visual Analogue Scale \[VAS\] and Numeric Rating Scale \[NRS-11\]), functional ability (using Oswestry Disability Index scores), serum Interleukin-6 levels, and overall safety. All participants received fluoroscopy-guided PRF at 42°C for three 120-second cycles and were followed for approximately 6 weeks.
Detailed description
Consecutive patients who met the inclusion and exclusion criteria were enrolled and randomized into two groups: the intervention group (high-voltage PRF, 60 V) and the control group (low-voltage PRF, 45 V). The sample size was calculated using the Neyman-Pearson approach with a superiority hypothesis, assuming that the intervention group would achieve greater pain reduction than the control group. Accounting for an estimated 20% dropout rate, 11 participants were required per group. Patients who voluntarily withdrew from the study were excluded from analysis, whereas patients who discontinued the intervention due to adverse effects during or after the procedure were included in the analysis and reported.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Pulsed Radiofrequency | A specialist performed fluoroscopy-guided monopolar Pulsed Radiofrequency (PRF) on a prone patient using a 22-gauge cannula (Cosman CC, CR type, 10 cm with a 10 mm active tip). Sensory stimulation prior to the procedure was applied at 200 Ohm, 50 Hz (threshold: 0.3 - 0.5 V), and motor stimulation at 2 Hz (threshold: 0.9 - 1.5 V). PRF was applied at a maximum temperature of 42 centigrade, with a frequency of 2 Hz, pulse width of 20 milliseconds, and a duration of 120 seconds per cycle for three cycles. An operating room nurse set the voltage at 45 V or 60 V. |
| DRUG | Post-operative Analgesia | Post-procedure analgesia in both groups was provided via IV fentanyl 0.5-1 µg/kg, administered as needed for patients reporting an NRS score greater than 4. This intervention was not a primary focus of the study. |
Timeline
- Start date
- 2025-02-07
- Primary completion
- 2025-04-29
- Completion
- 2025-04-29
- First posted
- 2025-12-24
- Last updated
- 2025-12-24
Locations
1 site across 1 country: Indonesia
Source: ClinicalTrials.gov record NCT07303309. Inclusion in this directory is not an endorsement.