Clinical Trials Directory

Trials / Recruiting

RecruitingNCT07293936

Post-Filter Hematocrit

Validation of a Post-Filter Hematocrit Calculation Formula: A Comparative Analysis With Measured Post-Filter Hematocrit Values

Status
Recruiting
Phase
N/A
Study type
Interventional
Enrollment
20 (estimated)
Sponsor
Gwyndolyn M. Radford · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

Filter clotting is a major complication of continuous renal replacement therapy (CRRT), resulting in blood loss, reduced treatment efficacy, and increased cost. One modifiable factor associated with filter clotting is filtration fraction (FF), or the proportion of plasma water being removed from the blood over the course of the filter. In convention, a cutoff of FF\<20-30% has been used to prevent hemofilter clotting, but no evidence correlating FF with hemofilter clotting has been documented. Some experts have proposed that post-filter hematocrit (Hct) could be a more direct marker for determining hemofilter clotting risk, but evidence supporting clinical utility of this marker is lacking. HCTpost=HCTpre/(FF(HCTpre-1)+1) In our proposed validation study, we hope to determine whether our formula for post-filter Hct provides accurate results when compared to measured values. The information obtained from this study will potentially justify the use of utilizing the formula in future studies. The procedure of this study is collecting blood samples from the post-filter lines of patients on CRRT at different time points and different flow rates. This will be considered the "measured post-filter hematocrit" which will then be compared to the calculated formula above, using the other values obtained from daily labs (for pre-filter hematocrit) and CRRT machine settings.

Detailed description

This investigational study is listed as "other" because it is a validation study comparing two measurement methods-comparing a calculated versus a machine-measured post-filter hematocrit- and is typically classified as a cross-sectional investigational study in the context of diagnostic or method comparison research.

Conditions

Interventions

TypeNameDescription
OTHERCalculated Post-Filter Hematocritusing the formula: HCTpost=HCTpre/(FF(HCTpre-1)+1)
OTHERMeasured Post-Filter HematocritMeasured from blood sample taken from CRRT machine

Timeline

Start date
2025-03-15
Primary completion
2026-02-01
Completion
2026-03-15
First posted
2025-12-19
Last updated
2025-12-19

Locations

1 site across 1 country: United States

Source: ClinicalTrials.gov record NCT07293936. Inclusion in this directory is not an endorsement.