Trials / Not Yet Recruiting
Not Yet RecruitingNCT07260721
Evaluation of a Single-lead ECG Patch-based Telemetry System for In-hospital Monitoring
Investigator-initiated Trial to Evaluate the Performance and Utility of a Single-lead Electrocardiogram Patch-based Telemetry System in Patients Requiring In-hospital Telemetry Electrocardiogram Monitoring During Hospitalization
- Status
- Not Yet Recruiting
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 100 (estimated)
- Sponsor
- Yonsei University · Academic / Other
- Sex
- All
- Age
- 19 Years
- Healthy volunteers
- Not accepted
Summary
"This investigator-initiated, prospective, single-center clinical study evaluates the performance and clinical utility of a single-lead electrocardiogram (ECG) patch-based telemetry system for hospitalized patients who require in-hospital telemetry ECG monitoring. The system integrates real-time centralized surveillance (MEMO-Cue) with post-hoc analytic review (MEMO-Care) using ECG signals recorded by the MEMO Patch M, aiming to enable timely recognition of clinically important arrhythmias and to inform treatment decisions under routine inpatient conditions. Adults (≥19 years) indicated for continuous ECG monitoring during admission are enrolled after written informed consent, with a planned sample size of 100 to yield approximately 90 evaluable participants (10% anticipated dropout). The design does not include randomization or blinding. Study procedures include a screening visit (eligibility and baseline data), an inpatient monitoring period of at least 12 hours and up to 8 days with simultaneous MEMO-Cue monitoring and MEMO Patch M recording, and an end-of-visit assessment when MEMO-Care analytic results become available. Concomitant therapies deemed clinically necessary are permitted and documented, and adverse events are prospectively assessed. Clinical utility endpoints quantify care impact and timeliness: (1) rate of treatment plan changes (e.g., initiation or modification of anticoagulants or antiarrhythmic drugs, cardioversion scheduling, device implantation, or other actions); (2) time to recognition (days) of major arrhythmias-atrial fibrillation (AF), ventricular tachycardia (VT), pause, ventricular premature complex (VPC), and supraventricular tachycardia (SVT)-based on MEMO-Cue alarms or MEMO-Care results with objective confirmation; (3) reduction ratio in recognition time when identified earlier by MEMO-Cue versus MEMO-Care; and (4) proportion of participants with shortened recognition time by MEMO-Cue. Clinical performance endpoints assess detection characteristics and agreement between MEMO-Cue alarms and MEMO-Care findings: (1) clinical sensitivity (true positive / \[true positive + false negative\]); (2) precision, i.e., positive predictive value (true positive / \[true positive + false positive\]); and (3) positive concordance rate (proportion of MEMO-Care-detected arrhythmias alerted by MEMO-Cue). Safety is captured as treatment-emergent adverse events after device application, including device-related skin reactions, detachment, or signal dropouts, with severity graded per NCI-CTCAE v5.0 and relationship to device recorded. By characterizing real-time patch-based telemetry alongside analytic review and its influence on diagnostic timing and management, the study aims to generate practical evidence supporting feasibility, reliability, and workflow compatibility of single-lead patch telemetry for in-hospital ECG monitoring.
Conditions
- Arrhythmias
- Atrial Fibrillation
- Ventricular Tachycardia
- Supraventricular Tachycardia
- Bradycardia
- Telemetry
- Patient Monitoring
- Hospitalization
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | MEMO-Cue-based telemetry monitoring | In-hospital telemetry electrocardiogram monitoring using the MEMO-Cue system, which integrates a single-lead patch-type Holter device (MEMO Patch M) with a central monitoring software (MEMO-Cue) and an analysis platform (MEMO Care). Participants requiring continuous ECG telemetry during hospitalization are monitored for at least 12 hours and up to 8 days to evaluate the system's clinical utility and performance in real-time arrhythmia detection compared with retrospective analysis using MEMO Care. |
Timeline
- Start date
- 2025-12-01
- Primary completion
- 2026-05-01
- Completion
- 2026-09-01
- First posted
- 2025-12-03
- Last updated
- 2025-12-03
Locations
1 site across 1 country: South Korea
Source: ClinicalTrials.gov record NCT07260721. Inclusion in this directory is not an endorsement.