Trials / Not Yet Recruiting
Not Yet RecruitingNCT07226869
Computer Guided Microwave Liver Ablation
- Status
- Not Yet Recruiting
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 100 (estimated)
- Sponsor
- NE Scientific INC · Industry
- Sex
- All
- Age
- 18 Years – 90 Years
- Healthy volunteers
- Not accepted
Summary
The goal of this clinical trial is to learn if the intraoperative use of a computer guidance software can improve the success of liver tumor ablation in adults. The employed software calculates and displays a simulation of the ablation such that the physician can visualize what portion of the target tumor has, and has not been treated at any point during the procedure. The main questions it aims to answer are: 1) Does the use of the computer guidance software reduce the number of times a tumor is incompletely treated. 2) Does the use of the computer guidance software reduce the rate of local tumor recurrence at 2 year follow-up? 3) Was there an increase or a decrease in medical problems for participants after a procedure where the guidance software was used? Researchers will compare liver tumor treatment using the computer guidance software with an historic control to see if the addition of the guidance software improved the outcomes after an ablation. Participants will: Undergo CT-guided microwave ablation treatment of a liver tumor using computer-assisted simulation. Visit the clinic at one month and then every 3 months for blood tests and a contrast-enhanced CT or MRI imaging study (as per standard of care)
Detailed description
Accublate (NE Scientific, Inc) is a computer-based tumor ablation guidance software that uniquely provides real-time simulation of expected ablation volumes. In a previously reported study of Radiofrequency Ablation, the improved visualization of treated versus untreated target tumor was associated with improved outcomes. This study examines clinical application of the simulation software for microwave ablation (MWA), which will be evaluated in a 24 month two-center clinical trial. At Dartmouth Hitchcock Medical Center (DHMC), and at one other hospital, under IRB approval, adults referred from local Liver Tumor Boards for curative local treatment of up to four Hepatocellular Carcinoma (HCC) tumors of 2-5 cm diameter will be offered participation. After providing informed consent, and meeting inclusion and exclusion criteria, the CT-guided MWA ablation will be performed, with the physician having the benefit of the graphical display of the Accublate MWA simulation guidance software. Prior to the ablation, the software provides 3D graphical display for planning, that includes the tumor, desired margin, and interactive model of the ablation probe and superimposed expected ablation volume at particular energy settings. During placement, the software permits registration of updated image of the actual probe position to original image of the segmented tumor, and with the interactive ablation volume settings, allows assessment of adequacy of targeting. After each activation of the ablation, the calculated simulated ablation volume is provided to indicate what tissues have, and have not, been ablated. These 3D views then provide guidance for intraprocedural adjustments to ensure target coverage by overlapping ablations, if indicated. Patients are routinely admitted for overnight observation and receive IV pain and nausea medication if needed. One month after the ablation, patients will have a follow-up outpatient contrast-enhanced abdominal CT, and from these images, the rate of complete ablation (Technical Efficacy) will be determined. Additionally, patients will be followed at 3 month intervals for 24 months after the ablation to detect any complications, tumor recurrence (Local Tumor Progression), and survival.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Computer-Assisted Microwave Liver Ablation | Computer-assisted image-processing software used intraoperatively to assist in percutaneous thermal ablation. The software performs segmentation and registration of pre-procedural and intraprocedural imaging, and simulates the expected ablation zone based on probe position, applied energy, and adjacent vascular structures. The output is displayed in 3D multiplanar images to be used by the treating physician to assist in planning, targeting, and intraprocedural decision-making regarding adequacy of ablation coverage. After each ablation activation, the treating physician determines registration accuracy and decides whether any additional ablation is required, based on images of the software estimation of what tissues have and have not been treated. |
Timeline
- Start date
- 2026-03-02
- Primary completion
- 2030-03-02
- Completion
- 2030-04-30
- First posted
- 2025-11-12
- Last updated
- 2025-11-12
Locations
1 site across 1 country: United States
Regulatory
- FDA-regulated device study
Source: ClinicalTrials.gov record NCT07226869. Inclusion in this directory is not an endorsement.