ArticuGrasp Trial: New Flexible Tool vs Standard Grasper for Lung Cancer Node Removal in Keyhole Chest Surgery

Overcoming Instrumentation Challenges in Real-World Uniportal Video-Assisted Thoracoscopic Surgery: A Prospective, Randomized, Controlled Trial Evaluating the SurgeoFlex Grasp Versus the Traditional Endograsper for Systemic Lymph Node Dissection in Patients With Early-Stage Non-Small Cell Lung Cancer

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
100 (actual)
Sponsor
Jianxing He · Academic / Other
Sex
All
Age
18 Years – 70 Years
Healthy volunteers
Not accepted

Summary

This study is testing whether a new, flexible surgical tool-the SurgeoFlex Grasp-makes keyhole chest operations for early-stage lung cancer easier, faster, and safer than the standard rigid tool used today. What is the problem? In keyhole (uniportal) chest surgery, formally known as single-port video-assisted thoracoscopic surgery (VATS), surgeons reach the lung through one small incision between the ribs. Because the operating space is tight, the usual stiff instruments can bump into each other and into surrounding tissues. This difficulty can prolong lymph-node removal and increase the risk of complications. What is being tested? The trial compares two handheld tools: SurgeoFlex Grasp (intervention): a slim, bendable grasper that can be steered around corners. Traditional EndoGrasper (control): a straight, rigid grasper currently used as the standard. Who is taking part? Approximately 100 adults with early-stage non-small-cell lung cancer (NSCLC) (tumours 3 cm or smaller) who are scheduled for keyhole surgery at The First Affiliated Hospital of Guangzhou Medical University. What will happen? Participants are allocated by randomisation into one of two groups: SurgeoFlex group-surgeons use the new flexible tool. Control group-surgeons use the standard rigid tool. All other aspects of the operation, anaesthesia, and post-operative care remain identical for both groups. What is measured? Lymphadenectomy time (duration required to remove the specified lymph nodes). Number of lymph nodes successfully removed. Frequency of surgical-instrument collisions or interference (instrument-clash events). Surgeon workload during the operation (assessed with the National Aeronautics and Space Administration Task Load Index \[NASA-TLX\]). Skin-incision length, pain scores (Visual Analogue Scale \[VAS\]), recovery time, infection rates, and overall cost. Quality-of-life scores one month after surgery (European Organisation for Research and Treatment of Cancer Quality-of-Life Questionnaire Core 30 \[EORTC QLQ-C30\] and its lung-cancer module \[EORTC QLQ-LC13\]). What is expected? The investigators expect the SurgeoFlex Grasp to shorten operative time, reduce instrument interference, lower surgeon stress, and accelerate recovery without increasing cost. How will this help patients? If the new tool performs as anticipated, future patients undergoing keyhole lung-cancer surgery may experience shorter operations, smaller scars, less pain, and lower infection risk while still obtaining complete cancer-related lymph-node removal. Where is the study taking place? The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China. Contact for more information: Clinical Research Management Committee 151 Yanjiang Road, Yuexiu District, Guangzhou 510120, China Email: crmc@gzhmu.edu.cn

Conditions

Interventions

TypeNameDescription
DEVICEArticulating lymph-node grasper (SurgeoFlex Grasp)Arm 1 - SurgeoFlex Grasp A single-use, low-profile articulating grasper with a 5-millimetre (mm) shaft and a 360-degree (360°) steerable distal tip. During uniportal video-assisted thoracoscopic surgery (UVATS), the device is introduced through the same 3-4-centimetre (cm) utility incision used for the camera and stapler. The flexible neck allows the jaws to approach hilar and mediastinal lymph nodes from multiple angles without repositioning the instrument shaft, thereby reducing instrument collision and chest-wall torque.
DEVICEArm 2 Intervention Name Traditional rigid endograsperArm 2 - Traditional Rigid EndoGrasper A reusable, straight-shafted 5 mm grasper with fixed-angle jaws identical to those used in conventional multi-port video-assisted thoracoscopic surgery (VATS). The instrument is passed through the single 3-4 cm incision in the same fashion as the SurgeoFlex Grasp, but its rigid shaft limits the working angle and often requires external repositioning of the entire instrument to reach deep lymph-node stations.

Timeline

Start date
2025-01-01
Primary completion
2025-03-31
Completion
2025-03-31
First posted
2025-10-01
Last updated
2025-10-01

Locations

1 site across 1 country: China

Source: ClinicalTrials.gov record NCT07201077. Inclusion in this directory is not an endorsement.