Clinical Trials Directory

Trials / Recruiting

RecruitingNCT07199153

Accuracy of 3D Printed Custom-Made Registration Method for Dynamic Navigation Implant Surgery Using Mininavident in the Esthetic Zone: A Clinical Trial

Status
Recruiting
Phase
N/A
Study type
Interventional
Enrollment
10 (estimated)
Sponsor
Sherif Aly Sadek · Academic / Other
Sex
All
Age
Healthy volunteers
Not accepted

Summary

This clinical trial evaluates the accuracy of a 3D printed custom-made registration method for dynamic navigation implant surgery using the Mininavident system in the esthetic zone of the anterior maxilla. Ten patients with a single missing anterior tooth will undergo CBCT-based planning, intraoral scanning, and guided implant placement using 3D printed registration markers. Postoperative CBCT analysis will measure deviations between planned and placed implants in terms of angular, coronal, and apical positions. The study aims to determine whether 3D printed markers provide clinically acceptable accuracy (\<2 mm, \<5°) and to assess their feasibility as a reproducible alternative to standard registration methods.

Detailed description

Accurate implant positioning is essential for esthetic and functional success, particularly in the anterior maxilla. Dynamic navigation systems (DNS) provide real-time guidance but depend on reliable registration between patient anatomy and virtual planning. Errors may occur with conventional fiducial markers, highlighting the need for more precise methods. This clinical trial investigates the use of 3D printed custom registration markers with the Mininavident DNS for implant placement in the esthetic zone. Ten patients with a single missing anterior tooth will undergo CBCT-based planning and guided implant placement using the custom markers. Postoperative CBCT scans will be compared with preoperative plans to measure positional and angular deviations. The primary outcome is the accuracy of implant placement, with deviations expected to remain within clinically acceptable limits (\<2 mm, \<5°). Secondary outcomes include assessing the feasibility and reproducibility of incorporating 3D printed registration into DNS workflows. Results may validate this approach as a cost-effective, patient-specific solution to enhance precision and predictability in implant dentistry.

Conditions

Interventions

TypeNameDescription
DEVICED Printed Custom Registration Marker for Dynamic NavigationA patient-specific, 3D printed registration marker designed for use with the Mininavident dynamic navigation system. The marker is fabricated based on CBCT and intraoral scans, enabling accurate registration between virtual planning and clinical implant placement in the esthetic zone. Accuracy of placement is assessed through postoperative CBCT superimposition.

Timeline

Start date
2025-08-10
Primary completion
2025-09-30
Completion
2025-10-15
First posted
2025-09-30
Last updated
2025-09-30

Locations

1 site across 1 country: Egypt

Source: ClinicalTrials.gov record NCT07199153. Inclusion in this directory is not an endorsement.