Clinical Trials Directory

Trials / Recruiting

RecruitingNCT07177586

New-Generation GMA Laryngeal Mask Airway Versus Conventional Inflatable Laryngeal Mask Airway

A Multicenter, Randomized Controlled Study Comparing the Effectiveness of the New Generation GMA Laryngeal Mask and Conventional Laryngeal Mask in Airway Management During General Anesthesia

Status
Recruiting
Phase
N/A
Study type
Interventional
Enrollment
1,384 (estimated)
Sponsor
First Affiliated Hospital of Zhejiang University · Academic / Other
Sex
All
Age
18 Years – 75 Years
Healthy volunteers
Not accepted

Summary

This study aims to compare the new-generation GMA laryngeal mask airway (LMA) with the traditional inflatable LMA in patients undergoing elective surgery under general anesthesia. The primary objectives are to evaluate the safety, effectiveness, stability, ease of use, and patient comfort of the GMA LMA, providing practical guidance for clinical airway management. Additionally, this research will analyze the anatomical positioning and sealing mechanism of the LMA to identify factors influencing proper alignment and airway sealing. The findings may contribute to future improvements in LMA design, enhancing patient safety and procedural success. This study is designed for healthcare providers, anesthesiologists, and researchers seeking evidence-based recommendations for LMA selection in clinical practice. Participation involves standard anesthesia procedures with close monitoring to ensure patient safety.

Detailed description

Eligible patients meeting the inclusion criteria were enrolled in the study and randomly assigned into two groups using a random number table: the traditional Inflatable Laryngeal Mask Airway Group (Group L) and the GMA Group (Group G). One day before surgery, the research team conducted preliminary screening of patients scheduled for elective surgery, followed by a preoperative visit to explain the study's purpose, anesthesia considerations, and obtain informed consent. Upon entering the operating room, standard monitoring (ECG, blood pressure, pulse oximetry, etc.) was applied. The research team recorded the patient's actual fasting duration, last intake (food/liquid type), and baseline characteristics, including age, sex, height, weight, BMI, comorbidities, ASA classification, surgical type, and preoperative anxiety level. Airway assessment was reconfirmed. Anesthesia induction was performed with intravenous etomidate, vecuronium, and sufentanil. After loss of consciousness and disappearance of the eyelash reflex, manual ventilation was initiated. Following induction, the laryngeal mask was inserted.

Conditions

Interventions

TypeNameDescription
DEVICEGMA Laryngeal Mask AirwayThe GMA-Tulip is a new single-use supraglottic airway device (SAD). Device size is selected based on the patient's weight and height, following manufacturer guidelines.
DEVICEInflatable Laryngeal Mask AirwayThe comparator is a conventional inflatable Laryngeal Mask Airway (LMA) of appropriate size (selected by weight/height), inserted using standard clinical protocols.

Timeline

Start date
2025-09-18
Primary completion
2027-07-31
Completion
2027-07-31
First posted
2025-09-17
Last updated
2026-02-04

Locations

1 site across 1 country: China

Source: ClinicalTrials.gov record NCT07177586. Inclusion in this directory is not an endorsement.