Clinical Trials Directory

Trials / Not Yet Recruiting

Not Yet RecruitingNCT07108478

A Prospective, Multicenter, Observational Study of the Safety and Efficacy of Emergency Transcatheter Aortic Valve Replacement in Patients With Severe Aortic Stenosis

Status
Not Yet Recruiting
Phase
Study type
Observational
Enrollment
35 (estimated)
Sponsor
Qilu Hospital of Shandong University · Academic / Other
Sex
All
Age
70 Years
Healthy volunteers
Not accepted

Summary

The research name of this project is: A prospective, multicenter and observational study on the safety and effectiveness of emergency transcatheter aortic valve replacement (TAVR) in the treatment of patients with severe aortic stenosis. It is a prospective, multi-center clinical study, and 35 cases are planned to be enrolled and followed up for 12 months (before discharge, 30 days, 6 months and 12 months). The research instruments used are VitaFlow Liberty® transcatheter aortic valve and recoverable delivery system. The purpose of this study is to evaluate the safety and effectiveness of emergency TAVR in patients with severe aortic stenosis. The main end point is the cumulative all-cause mortality 12 months after operation, and the secondary end points mainly include adverse cerebrovascular events (MACCE), acute renal injury, implantation rate of permanent pacemaker and valve function.

Detailed description

The research name of this project is: A prospective, multicenter and observational study on the safety and effectiveness of emergency transcatheter aortic valve replacement (TAVR) in the treatment of patients with severe aortic stenosis. The prognosis of patients with severe aortic stenosis (AS) is extremely poor in emergency, and the mortality of traditional balloon angioplasty (PBAV) is high. As a new treatment method, emergency TAVR needs multi-center data to verify its safety and effectiveness. Based on the preliminary results of a single center, this study was extended to multiple centers in China, aiming at providing high-level evidence, helping to optimize the implementation strategy of emergency TAVR, and promoting its wide application in patients with severe aortic stenosis, thus improving the clinical prognosis and quality of life of patients. This study is a prospective, multi-center clinical study, and 35 patients are planned to be enrolled. All participants are followed up before discharge, 30 days, 6 months and 12 months after valve implantation, and the research unit independently manages data, including data collection, collation and statistical analysis. The research instruments used are VitaFlow Liberty® transcatheter aortic valve and recoverable delivery system. The purpose of this study is to evaluate the safety and effectiveness of emergency TAVR in patients with severe aortic stenosis. The main end point is the cumulative all-cause mortality 12 months after operation, and the secondary end points mainly include adverse cerebrovascular events (MACCE), acute renal injury, implantation rate of permanent pacemaker and valve function. The selection criteria are: patients with severe aortic stenosis diagnosed by medical treatment; Meet one of the emergency TAVR indications (shock, persistent ventricular tachycardia or ventricular fibrillation, unstable angina pectoris or chronic heart failure requiring mechanical circulatory assistance devices, etc.); Voluntary participation and signing of informed consent. The main exclusion criteria are: aortic root anatomy and lesions are not suitable for artificial valve implantation; Anatomical morphology or vascular diseases that affect the instrument approach; Left ventricular outflow tract obstruction; Primary dilated cardiomyopathy; Thrombosis in left ventricle; Patients who cannot receive anticoagulant or antiplatelet therapy, etc. The statistical methods used are descriptive analysis, Kaplan-Meier survival analysis and Cox proportional hazard model (SAS 9.4). Following the Helsinki Declaration, China's Quality Management Standard for Clinical Trials of Medical Devices and ISO 14155:2011, all patients signed informed consent forms with the approval of the Ethics Committee.

Conditions

Interventions

TypeNameDescription
DEVICETranscatheter aortic valve and recyclable delivery systemIn this study, the transcatheter aortic valve and its recycling delivery system were VitaFlow Liberty®, a TAVR product independently developed by Shanghai Minimally Invasive Cardiovascular Treatment Co., Ltd. (approved and marketed by NMPA). This product is equipment/consumables routinely purchased by hospitals. For routine clinical use, it is designed for transcatheter aortic valve implantation. The valve is delivered to the intended implantation site via the peripheral artery by retrograde flow through the delivery system, realizing the delivery, positioning and release of the valve. Under the supervision of medical imaging equipment, the valve is delivered to the lesion site of the aortic valve, and marked by the diseased aortic annulus, to release the valve and relieve the stenosis at the lesion site, thereby ensuring smooth aortic flow, improving cardiac function and achieving therapeutic purposes.

Timeline

Start date
2025-07-30
Primary completion
2028-02-28
Completion
2028-12-30
First posted
2025-08-07
Last updated
2025-08-07

Locations

1 site across 1 country: China

Source: ClinicalTrials.gov record NCT07108478. Inclusion in this directory is not an endorsement.