Clinical Trials Directory

Trials / Recruiting

RecruitingNCT07097584

Effect of Small Double-lumen Tube on the Intubation Time of Thoracoscopic Pulmonectomy in Asian Women

Effect of Small Double-lumen Tube on the Intubation Time of Thoracoscopic Pulmonectomy in Asian Women: a Randomized Controlled Clinical Trial

Status
Recruiting
Phase
N/A
Study type
Interventional
Enrollment
180 (estimated)
Sponsor
Zhejiang Cancer Hospital · Academic / Other
Sex
Female
Age
18 Years – 80 Years
Healthy volunteers
Not accepted

Summary

The purpose of this experiment is to verify whether selecting a double-lumen tube one size smaller based on the traditional personalized method can shorten the intubation time without increasing ventilation complications when performing tracheal intubation for thoracic surgery in Asian women.Patients receive double-lumen tubes of a size selected based on the traditional personalized method or one size smaller than that chosen by the traditional method during tracheal intubation. The primary outcome is the time duration required to complete Double-lumen tube intubation and positioning.

Detailed description

The selection of double-lumen tube sizes using traditional methods relies on two factors: height and gender. In this study, all patients planned to be enrolled are female, so the traditional corresponding relationship is roughly as follows: For patients with a height of less than 152 cm, a 32Fr (French) tube is often selected. For patients with a height between 152 - 165 cm, a 35Fr tube is often selected. For patients with a height between 165 - 177 cm, a 37Fr tube is often selected. For patients with a height of more than 177 cm, a 39Fr tube is often selected.

Conditions

Interventions

TypeNameDescription
DEVICESelecting the size of a Left Double-lumen endobronchialtube one size smaller than the traditional methodDuring tracheal intubation,choose a Left Double-lumen Endobronchial Tubethat is one size smaller than the traditional method.In this study, all patients planned to be enrolled are female. In experimental group the relationship between height and size is roughly as follows: For patients with a height between 152 - 165 cm, a 32Fr (French) tube is often selected. For patients with a height between 165 - 177 cm, a 35Fr tube is often selected. For patients with a height of more than 177 cm, a 37Fr tube is often selected.
DEVICESelecting the size of a Left Double-lumen endobronchialtube according to traditional methodsDuring tracheal intubation,choose the regular Left Double-lumen endobronchial tube according to the traditional method. The selection of double-lumen tube sizes using traditional methods relies on two factors: height and gender. In this study, all patients planned to be enrolled are female, so the traditional corresponding relationship is roughly as follows: For patients with a height of less than 152 cm, a 32Fr (French) tube is often selected. For patients with a height between 152 - 165 cm, a 35Fr tube is often selected. For patients with a height between 165 - 177 cm, a 37Fr tube is often selected. For patients with a height of more than 177 cm, a 39Fr tube is often selected.

Timeline

Start date
2025-07-15
Primary completion
2025-12-31
Completion
2025-12-31
First posted
2025-07-31
Last updated
2025-08-14

Locations

1 site across 1 country: China

Source: ClinicalTrials.gov record NCT07097584. Inclusion in this directory is not an endorsement.