Clinical Trials Directory

Trials / Not Yet Recruiting

Not Yet RecruitingNCT07042698

Evaluation of the Performance of Glomerular Filtration Rate Measurement Using CT Urography in Patients With a GFR Below 60 mL/Min/1.73 m²

Evaluation of the Performance of Glomerular Filtration Rate Measurement Using CT Urography in Patients With Chronic Kidney Disease

Status
Not Yet Recruiting
Phase
N/A
Study type
Interventional
Enrollment
70 (estimated)
Sponsor
Assistance Publique - Hôpitaux de Paris · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

Glomerular filtration rate (GFR), which is the main biomarker used in clinical practice to assess kidney function, is usually estimated from the serum concentration of endogenous markers such as creatinine and/or cystatin C. GFR estimation equations all share the disadvantage of imperfect accuracy due to non-GFR-related determinants of creatinine and cystatin C. When knowing the exact GFR value is necessary for clinical decision-making, measurement by clearance of an exogenous tracer is required. Various tracers are available, some of which are radioactive tracers (99mTc-DTPA and 51Cr-EDTA), while others are iodinated contrast agents (iohexol, iothalamate). GFR measurement procedures are time-consuming and require significant human resources (4 to 5 hours, or even 24 hours for plasma clearances at very low GFR values).Urinary clearance methods may be inaccurate in cases of inadequate voiding. Plasma clearance results may be inaccurate in cases of increased (overestimation) or decreased (underestimation) extracellular volume, low GFR (unless late sampling is performed), or glomerular hyperfiltration. Measuring tracers requires either warm labs for measuring radioactive markers or labs with HPLC (High Performance Liquid Chromatography) chains for iohexol, which are part of an external quality assurance program. The complexity and/or length of GFR measurement procedures, their cost, and laboratory constraints explain why measured GFR is underused in routine clinical practice. There is a critical need to develop GFR measurement methods that are simpler to implement, reliable across the entire GFR spectrum, and widely available. We have demonstrated that it is possible to measure GFR using 4-phase CT urography performed as part of the care of living kidney donor candidates (healthy individuals with normal GFR). The examination takes 10 minutes, requires no biological sampling, and is not subject to potential inaccuracies due to sodium overload or poor bladder emptying.

Detailed description

Objective: To assess whether GFR measurement using 4-phase CT urography is reliable in patients with GFR below 60 ml/min/1.73 m², as compared with iohexol clearance (reference method): - Unbiased (mean difference between CT-measured GFR and iohexol clearance not different from zero). - and accurate: at least 50% and 80% of GFR values measured by CT urography within 10% and 20% of biological clearance values for iohexol clearance. Method: Single-center interventional study. After performing a 4-phase CT urography (or 3-phase CT scan, with the addition of a 4th phase for research purposes), performed for clinical indications as part of the patient's care, and using iohexol as a contrast agent, patients will undergo a biological measurement of iohexol clearance, based on serum and urine samples taken over 4 periods of 1 hour, between 3 and 7 hours after the CT scan. No iohexol will be reinjected to measure GFR. The CT scan images will be segmented by the investigator to determine the CT-measured GFR. The inclusion criteria are: - Patients older than 18 years of age - Having given written consent to participate in the study. - Patient referred to the medical imaging department of the Henri Mondor University Hospital for a 3-phase or 4-phase abdominal CT scan. - With an estimated GFR according to CKD-EPIcreat2009 \< 60 ml/min/1.73m² - Hospitalized or outpatient. - Affiliated with French national health insurance. The exclusion criteria are: - Patients with hip implants, due to artifacts that make quantification of the contrast agent in the bladder unreliable. - Lack of health insurance - Patients under legal protection.

Conditions

Interventions

TypeNameDescription
OTHERGlomerular Filtration Rate measurement with iohexol clearanceAfter performing a 4-phase CT urography (or 3-phase CT scan, with the addition of a 4th phase for research purposes), performed for clinical indications as part of the patient's care, and using iohexol as a contrast agent, patients will undergo a biological measurement of iohexol clearance, based on serum and urine samples taken over 4 periods of 1 hour, between 3 and 7 hours after the CT scan. No iohexol will be reinjected to measure GFR. The CT scan images will be segmented by the investigator to determine the CT-measured GFR.

Timeline

Start date
2025-07-15
Primary completion
2027-07-14
Completion
2027-07-15
First posted
2025-06-29
Last updated
2025-06-29

Locations

1 site across 1 country: France

Source: ClinicalTrials.gov record NCT07042698. Inclusion in this directory is not an endorsement.