Trials / Recruiting
RecruitingNCT06999863
Oscillometric Blood Pressure Measurement: Evaluation of the Effect of Wearing a Sleeve and the Type of Measurement Algorithm
Measurements of Arterial Blood Pressure With an Automated Oscillometric Cuff: Evaluation of the Effect of Wearing a Sleeve and the Type of Measurement Algorithm. A Prospective Observational Single-center Study With an Invasive Reference
- Status
- Recruiting
- Phase
- —
- Study type
- Observational
- Enrollment
- 75 (estimated)
- Sponsor
- Nantes University Hospital · Academic / Other
- Sex
- All
- Age
- 18 Years – 99 Years
- Healthy volunteers
- Not accepted
Summary
For accurate measurements of arterial blood pressure (BP), international guidelines recommend placing the automated oscillometric cuff directly on the bare upper arm. However, for various reasons, cuffs are often applied over a layer of textile. Whether this practice affects the reliability of the readings remains uncertain. Using a rigorous methodology, the CASBA study aims at addressing this issue. Additionally, two different BP measurement algorithms are available in some oscillometric monitors. To our knowledge, no study has compared the performance of these two algorithms. This study will help determine which oscillometric algorithm should be given priority in intensive care facilities.
Detailed description
The automated oscillometric cuff is the predominant non-invasive method for measuring BP. For accurate measurements, international guidelines recommend placing the cuff directly on a bare upper arm. However, for reasons of convenience, hygiene, comfort, cultural or religious practices, or skin reactions, cuffs are often applied over a layer of textile. Some authors suggest this practice does not significantly affect BP readings, while other authors are more cautious or even advise against it. Prior studies are not devoid of limitations. Further research into sleeve effects on BP measurement accuracy is warranted. The present study project employs rigorous methodology and leverages invasive arterial catheters for reliable reference measurements. Additionally, the broad range of BP levels in surgical intensive care units ensures comprehensive data, including mean, systolic, and diastolic BP (MBP, SBP, and DBP). Additionally, some oscillometric monitors incorporate two reference algorithms for BP measurement: * Auscultatory Reference Algorithm: Calibrates oscillometric measurements to align with manual cuff and stethoscope values. This is the default setting. * Invasive Reference Algorithm: Adjusts non-invasive BP values to approximate invasive measurements. Health care providers are, in our experience, rarely aware of the existence of these two distinct algorithms. Although the reference auscultatory algorithm is generally recommended for routine non-invasive monitoring, such as at home or in a clinic, the invasive reference algorithm might be preferable in critical care settings. Importantly, in the absence of published studies on the subject, these considerations remain speculative. However, it is important to determine which oscillometric algorithm should be prioritized in critical care settings, where invasive measurement serves as the reference. This will be a secondary objective of this study.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| OTHER | Patients of a surgical intensive care unit | Patients of a surgical intensive care unit having an arterial catheter undergoing noninvasive measurements of BP in 3 situations (thick sleeve, thin sleeve, bare arm) and with 2 algorithms (for bare arm measurement only). |
Timeline
- Start date
- 2025-07-24
- Primary completion
- 2026-07-01
- Completion
- 2026-07-01
- First posted
- 2025-05-31
- Last updated
- 2025-08-22
Locations
1 site across 1 country: France
Source: ClinicalTrials.gov record NCT06999863. Inclusion in this directory is not an endorsement.