Clinical Trials Directory

Trials / Completed

CompletedNCT06995560

Effects of Transcranial Electrical Stimulation on Task Performance in Healthy Adults

Preliminary Investigations of Transcranial Electrical Stimulation Effects on Neurophysiology and Behavior

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
40 (actual)
Sponsor
Massachusetts General Hospital · Academic / Other
Sex
All
Age
25 Years – 55 Years
Healthy volunteers
Accepted

Summary

The objective of this randomized, double-blind, sham-controlled, crossover study is to evaluate the effects of transcranial electrical stimulation (tES) on complex cognitive task performance in healthy adult volunteers. The primary questions this study aims to answer are: 1. Does tES improve task performance, including speed, accuracy, and overall success, during a computerized track-and-capture task? 2. Do different stimulation targets produce differential effects on performance? 3. Are there short-term post-stimulation effects on task performance (up to 48 hours)? Participants will: 1. Complete two testing sessions under either active or sham stimulation conditions. 2. Perform a complex operational task involving dual-hand controllers while undergoing tES or sham stimulation, and immediately after. 3. Return for follow-up task performance assessments at 24 and 48 hours post-stimulation to evaluate after-effects.

Detailed description

Transcranial electrical stimulation (tES) is a non-invasive neuromodulation technique that delivers low-intensity electrical currents (e.g., \<2 mA) through scalp electrodes to modulate brain activity. Numerous studies have shown that tES can enhance cognitive functions such as learning, memory, attention, and decision-making in healthy individuals, as well as provide therapeutic benefits in psychiatric and neurological populations. Despite these findings, substantial knowledge gaps remain regarding the effects of tES, particularly in the context of complex, operationally relevant tasks. Existing research has primarily focused on the effects of tES on simple cognitive tasks, with limited investigation into task that require multiple cognitive domain to operate simultaneously. Performance on complex tasks, such as those involving motor coordination, visual-spatial process, decision-making, and rapid response, may respond differently to tES than simple, isolated tasks. Understanding these effects could have broad applications in optimizing cognitive performance across various high-demand settings. This study is designed to address several key uncertainties: 1. Inter-individual variability in behavioral and neurophysiological responses to tES. 2. the impact of stimulation parameters (location, type, intensity) on task performance. 3. The magnitude and duration of both immediate and post-stimulation effects on behavior. To investigate these questions, healthy adults perform a computerized track-and-capture task requiring real-time motor control and decision-making using dual-hand controllers. Participants undergo both active and sham stimulation in a randomized, double-blind, crossover design. Stimulation will target either the left dorsolateral prefrontal cortex or the left anterior insula, guided by current flow modeling software. Performance is assessed during stimulation, immediately after, and at 24 and 48 hours post-stimulation to evaluate both immediate and short-term after-effects. Outcome measures include task performance metrics (e.g., speed, accuracy, overall success) and neurophysiological data collected via non-invasive monitoring with functional near-infrared spectroscopy (fNIRS). The study is part of a broader research effort to characterize the functional impact of tES on complex behavior and to inform future applications in cognitive performance enhancement. All stimulation procedures follow established safety guidelines for low-intensity tES, including continuous monitoring of electrode impedance and post-session adverse event questionnaires assessing discomfort, mood, and cognitive status. The Soterix Medical MXN-33 HD-tES system includes built-in safeguards to prevent excessive current delivery and to ensure safe electrode contact throughout the stimulation. Participants serve as their own controls in a within-subject crossover design, increasing statistical power for detecting within-subject differences between active and sham conditions.

Conditions

Interventions

TypeNameDescription
DEVICEActive Transcranial Electrical StimulationActive tES delivered using the Soterix Medical MXN-33 HD-tES stimulator. Stimulation is applied via high definition electrodes targeting either the left DLPFC or L-aINS at intensities up to 1.9 mA. Stimulation is performed for up to 45 minutes during task execution. Participants perform the ROBoT-r task during stimulation.
DEVICESham Transcranial Electrical StimulationSham tES using the same Soterix Medical MXN-33 HD-tES stimulator and electrode placements. Stimulation ramps up and down over 20 seconds to mimic sensation but provides no continuous current. Participants perform the ROBoT-R task under sham conditions.

Timeline

Start date
2020-10-25
Primary completion
2024-10-31
Completion
2024-10-31
First posted
2025-05-29
Last updated
2025-05-29

Locations

1 site across 1 country: United States

Regulatory

Source: ClinicalTrials.gov record NCT06995560. Inclusion in this directory is not an endorsement.