Clinical Trials Directory

Trials / Recruiting

RecruitingNCT06983652

Validation of the Use of Terahertz Scanning System on Corneal Scars and Corneal Edema

Validation of the Use of Terahertz Scanning System on Corneal Scars and Corneal Edema: Phase II Clinical Trial

Status
Recruiting
Phase
Study type
Observational
Enrollment
150 (estimated)
Sponsor
Singapore Eye Research Institute · Academic / Other
Sex
All
Age
21 Years
Healthy volunteers
Not accepted

Summary

This observational study aims to validate the use of THz scanning system in corneal edema and corneal scars, and to investigate the accuracy and performance on the use of THz scanning system in the evaluation of the progression of corneal edema and corneal scars. Participants corneal scars and corneal edema will undergo THz scanning, followed by a series of conventional clinical examinations for detailed characterization of the corneal lesion. The performance of the use of THz system on corneal scars and edema will be evaluated by correlating measurements from the THz scans with those obtained from standard clinical methods. The investigators hypothesize that the THz scanning system has the capacity to evaluate the hydration level on human corneas.

Detailed description

Corneal opacity is one of the main causes of low vision and visual impairment, which results from two pathological etiologies: corneal edema and corneal scarring. When corneal opacity progresses to end-stage disease, the only option is to undergo a corneal transplantation. There is a global shortage of donor corneas and patients who undergo corneal transplantation require life-long topical immunosuppressant treatment, hence monitoring the progression of corneal edema or corneal scarring to prevent the disease entering into the end stage is crucial. Monitoring the progression of diseases also allows surgeons to do earlier intervention with less invasive techniques, such as lamellar corneal graft, as opposed to full-thickness graft. Currently there is no objective tool clinically to quantitatively evaluate corneal opacity and there is no tool to directly evaluate corneal hydration level. Hence, there is a need to develop a quantitative tool to evaluate the density of corneal opacities. There is a need to develop a medical tool to evaluate the corneal scar objectively and quantitatively, to better monitor the disease progression and aid in the surgical decision making. Terahertz (THz) waves are electromagnetic radiation, and have emerged as a novel, non-invasive and non-contact imaging modality in the biomedical field, with a fast-scanning speed (30ms per scan) to meet medical diagnostic needs. With its fast scanning, it provides a more accurate result for the estimation of corneal thickness. Its high sensitivity hydration absorption and characterization peaks of collagen will provide a useful tool to obtain information that are related to the corneal layers. Water has a high dielectric constant and is highly absorptive to THz spectrum. This allows THz wave to be highly sensitive to water content in tissue. Furthermore, THz scan has been applied to a variety of hydration-related diseases or conditions. With THz scan, early detection of disease and diagnosis can be carried out. Some examples would be the prediction of skin flap failure, diagnosis for the presence of caries lesion at its initial stage, identification of skin cancer in skin biopsy samples and to access the physiological dynamics of tear film in dry eye syndrome. Previous studies have demonstrated that THz scanning system could be used as an early diagnostic tool, to identify the cancerous area based on the lack of clear cellular order in the skin. It was able to detect disease conditions in deeper layers, allowing it to be an effective early diagnostic tool for basal cell carcinoma. Moreover, it had been confirmed that THz scanning system had the sensitivity to identify the difference in colon tissue composition. The findings showed that the properties of ex vivo tissue, had an increase in both absorption coefficient and refractive indices in disease tissue when compared to healthy tissue. A recent study showed that with THz scanning system, clinicians will be able to obtain different images, such as 3D imaging methods to provide multiple views of internal structures. Furthermore, with the THz scan, the process of water loss in an in vitro porcine corneal tissue could be determined using a THz reflection imaging system. It was found that THz wave was approximately linear to the water content concentration, and that the slope decreased monotonously with an increase in frequency. Thus THz imaging is suggested to be used for the clinical diagnosis of corneal edema or scars, dry eye diseases and corneal hydration in refractive surgery. The investigators would like to conduct the clinical trial to validate the use of THz scanning system in human corneal edema and corneal scars.

Conditions

Interventions

TypeNameDescription
DEVICETHz scanning using THz Imaging system.The THz scanning system is non-invasive and non-contact. It is a prototype developed by Institute of Materials Research and Engineering (IMRE), A\*STAR, Singapore and is performed for the purpose of research. THz scanning will provide safety data in human and the measurement of cornea hydration status. Each THz scan will take approximately 1 second. Real-time data will be generated when participants are positioned in front of the device.

Timeline

Start date
2024-07-01
Primary completion
2026-06-30
Completion
2026-08-31
First posted
2025-05-21
Last updated
2025-05-21

Locations

1 site across 1 country: Singapore

Source: ClinicalTrials.gov record NCT06983652. Inclusion in this directory is not an endorsement.