Trials / Completed
CompletedNCT06973044
Continuous vs Intermittent Monitoring of Respiratory and Heart Rate in Relation to Length of Stay
Comparison Between Continuous and Intermittent Monitoring of Abnormal Respiratory and Heart Rate in Relation to Length of Stay. A Clinical Multicenter Study of Continuous Wireless Monitoring Within the NIGHTINGALE Project
- Status
- Completed
- Phase
- —
- Study type
- Observational
- Enrollment
- 46 (actual)
- Sponsor
- Karolinska Institutet · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
Is heart rate and respiratory rate measured continuously with a new wireless sensor better as compared to standard care, with manually measured spot checks by nurses on general wards? Does continuous monitoring detect more abnormal respiratory- and heart rate? Are abnormal values associated with increased lenght of stay?
Detailed description
Tachypnea is not just a sign of ventilatory problems with hypoxia, but also a precursor of sepsis, metabolic acidosis and severe pain reflecting its role as an indicator of severe derangement in many body systems. A high respiratory rate has been shown to be the most reliable vital sign to predict clinical deterioration, cardiac arrest and is even associated with higher mortality rates. Despite this, it is the vital parameter most neglected; poorly documented or not recorded at all. Studies have shown that respiratory rate is measured in less than half of cases consequently jeopardizing patient safety. The lack of understanding why respiratory rate is important and its superiority to pulse oximetry in predicting clinical deterioration may be one of the reasons why it is not measured accurately. Badawy and colleagues stated in their study "Is everyone really breathing 20 times a minute?" that respiratory rate was inaccurately recorded and had little variation in the recordings, even in patients with cardiopulmonary compromise, findings that's been supported with later studies. Respiratory rate has traditionally not been objectively measured in general wards, but instead calculated manually over 30 seconds or a minute. This could be changed by new wireless monitoring technology. A recent large study showed that continuous measured respiratory rate together with heart rate and age in a clinical deterioration model outperformed traditional early warning scores in predicting ICU admission. The present study evaluates heart rate and respiratory rate measured continuously with a new wireless sensor as compared to standard care, with manually measured spot checks by nurses on general wards.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Checkpoint Cardio wireless continuous monitoring device | Continuous monitoring of respiratory rate and heart rate |
Timeline
- Start date
- 2020-11-01
- Primary completion
- 2021-09-30
- Completion
- 2024-12-31
- First posted
- 2025-05-15
- Last updated
- 2025-05-15
Locations
2 sites across 1 country: Sweden
Regulatory
- FDA-regulated device study
Source: ClinicalTrials.gov record NCT06973044. Inclusion in this directory is not an endorsement.