Clinical Trials Directory

Trials / Completed

CompletedNCT06920823

Comparison of Antegrade and Retrograde Fixation With Intramedullary Screws in Metacarpal Fractures

Comparison of Antegrade and Retrograde Fixation With Intramedullary Headless Canulated Screws in Patients With Metacarpal Fractures

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
22 (actual)
Sponsor
Pamukkale University · Academic / Other
Sex
All
Age
18 Years – 65 Years
Healthy volunteers
Not accepted

Summary

Purpose: Intramedullary fixation has proven to be an efficacious intervention for metacarpal fractures. Advantages involve stable fixation facilitating early surgical rehabilitation and higher fracture union rates, without increased morbidity. We aimed to compare the results of fixation of metacarpal fractures with headless cannulated screws towards antegrade or retrograde on pain, function and quality of life in patients with metacarpal fractures. Methods: Patients admitted to Pamukkale University Orthopedics and Traumatology Department, due to metacarpal fracture were prospectively included in the study and randomly grouped. A total of 22 patients and 26 metacarpal fractures were assessed. Group I patients were operated with antegrade(proximal entry) , and group II with retrograde (distal entry) , using intramedullary headless cannulated screws. Appropriate screw selection was made by measuring the metacarpal isthmus diameter of the patient's x-ray results (AP and oblique direction). We used headless cannulated screws with diameters between 3.5mm and 5mm in the fractures.

Detailed description

This was a prospective randomised comparative single-blinded study comparing the effects of intramedullary fixation direction and entry site in patients with metacarpal fractures. The participants were first evaluated at post-operative 6th week and the last evaluation was performed at post-operative 12th week The evaluations included radiographic union, grip strength measurement (with Jamar hydraulic hand dynamometer), range of motion measurement (compared to the opposite hand), and Michigan Hand Outcome Questionnaire (MHQ) questionnaire. All assessments were performed by the same investigator. The researcher who performed the evaluations did not know which group the participants were in. In the antegrade headless cannulated screw fixation technique, a small incision was made on the extensor aspect of the fractured metacarpal at the level of the carpometacarpal (CMC) joint and the extensor tendon was excised. After fracture reduction, k-wire was inserted intramedullarly. After appropriate drilling, 1 headless cannulated screw was applied distally.(figure 1) In the fixation technique with retrograde headless cannulated screw, a small incision was made on the extensor side of the fractured metacarpal at the level of the MCP joint, and the extensor tendon split was passed. After fracture reduction, k-wire was inserted intramedullarly. After appropriate drilling, headless cannulated screw was applied proximally.

Conditions

Interventions

TypeNameDescription
PROCEDUREantegrade (proximal entry) fixationIn the antegrade headless cannulated screw fixation technique, a small incision was made on the extensor aspect of the fractured metacarpal at the level of the carpometacarpal joint.
PROCEDUREretrograde (distal entry) fixationIn the fixation technique with retrograde headless cannulated screw, a small incision was made on the extensor side of the fractured metacarpal at the level of the metacarpophalangeal joint.

Timeline

Start date
2021-10-04
Primary completion
2024-09-25
Completion
2024-09-25
First posted
2025-04-10
Last updated
2025-04-10

Locations

1 site across 1 country: Turkey (Türkiye)

Source: ClinicalTrials.gov record NCT06920823. Inclusion in this directory is not an endorsement.