Clinical Trials Directory

Trials / Recruiting

RecruitingNCT06913088

Ultrasonication-mediated Microbubbles Dressing for Hand Arthritis

Ultrasonication-mediated Microbubbles Dressings Increase the Therapeutic Efficacy of Piroxicam Gel for Hand Arthritis: Assessments Using Conventional and Ultrafast Power Doppler Imaging

Status
Recruiting
Phase
N/A
Study type
Interventional
Enrollment
60 (estimated)
Sponsor
National Taiwan University · Academic / Other
Sex
All
Age
20 Years
Healthy volunteers
Not accepted

Summary

The goal of this clinical trial is to learn if ultrasonication-mediated microbubbles dressing works to treat hand arthritis in adults. It will also learn about the safety of ultrasonication-mediated microbubbles dressing. The main questions it aims to answer are: Does ultrasonication-mediated microbubbles dressing increase the therapeutic efficacy of piroxicam gel for hand arthritis? Researchers will compare "ultrasonication-mediated microbubbles dressing + piroxicam gel " to "ultrasonication + piroxicam gel" and "piroxicam gel alone" to see if ultrasonication-mediated microbubbles dressing works to treat hand arthritis. Participants will: Take "ultrasonication-mediated microbubbles dressing (day 1,3,5) + piroxicam gel (day 2,4,6,7) ", "ultrasonication (day 1,3,5) + piroxicam gel (day 2.4.6.7)", and "piroxicam gel alone (day 1-7)" for 1 week. Visit the clinic on day 1 and day 8 for checkups and tests Keep a diary of their symptoms

Conditions

Interventions

TypeNameDescription
PROCEDUREultrasonication-mediated microbubbles dressingThe microbubble suspension is diluted with normal saline to a concentration of 2x10\^7 bubbles/mL, applied to a gauze cloth, and covered on the joint skin surface. The joint is ultrasonicated for 3 minutes using an ultrasonic implanter (KUM-2000, NEO-TEC, Taipei, Taiwan), and then piroxicam gel is applied. The parameter values for ultrasonication are duty cycle 0.5, Tempo 10, intensity 70%, and time 3 min. This treatment is performed on day 1, 3, and 5.
PROCEDUREultrasonication using pure gelThe joint is ultrasonicated for 3 minutes using an ultrasonic implanter (KUM-2000, NEO-TEC, Taipei, Taiwan) with pure gel, and then piroxicam gel is applied. The parameter values for ultrasonication are duty cycle 0.5, Tempo 10, intensity 70%, and time 3 min. This treatment is performed on day 1, 3, and 5.

Timeline

Start date
2025-04-02
Primary completion
2025-07-01
Completion
2026-03-31
First posted
2025-04-06
Last updated
2025-04-17

Locations

1 site across 1 country: Taiwan

Source: ClinicalTrials.gov record NCT06913088. Inclusion in this directory is not an endorsement.