Clinical Trials Directory

Trials / Recruiting

RecruitingNCT06852911

FeNO Detection in Asthma Diagnosis: A New Technology Approach

The Diagnostic Significance of Exhaled Nitric Oxide (FeNO) With a Novel Technology in the Assessment of Bronchial Asthma

Status
Recruiting
Phase
N/A
Study type
Interventional
Enrollment
170 (estimated)
Sponsor
Novlead Inc. · Industry
Sex
All
Age
18 Years
Healthy volunteers
Accepted

Summary

The detection of exhaled nitric oxide (FeNO) represents a non-invasive, safe, and rapid approach for assessing endogenous nitric oxide (NO) levels within the airway. FeNO concentrations are closely associated with airway inflammation and hyperresponsiveness, and are currently recognized as biomarkers indicative of type II airway inflammation. Recent advancements in nitric oxide detection technology for both upper and lower airways, as well as for small and large airways, have provided significant insights for the diagnosis and management of conditions such as bronchial asthma, chronic cough, upper airway diseases, chronic obstructive pulmonary disease, and even rare airway disorders. Presently, FeNO measurement is frequently employed in the differential diagnosis and monitoring of airway inflammatory diseases. The FeNO test is conducted using a FeNO test analyzer. Internationally, FeNO detection analyzers utilize three primary methodologies: chemiluminescence, laser, and electrochemical techniques. Among these, chemiluminescence is regarded as the "gold standard" globally. However, due to technical constraints, this methodology has not been clinically accessible within domestic settings. In China, the electrochemical FeNO analyzer is predominantly utilized, characterized by its compact size and portability. Nonetheless, this method necessitates patient cooperation during inhalation and exhalation, rendering it impractical for individuals who are unable to comply, such as children, the elderly, and severely ill patients. Consequently, FeNO detection poses significant challenges for these populations in China, representing a notable clinical gap. The newly implemented technology employs an innovative domestic chemiluminescence FeNO analyzer, which is exclusively available in China. This analyzer, owing to its methodological advantages, is capable of obtaining FeNO detection values from patients' natural breathing patterns, facilitating rapid response and comprehensive FeNO assessment without requiring patient cooperation. This approach, referred to as the "Tidal-breathing of FeNO" enables the completion of FeNO assessments in patients who are unable to engage in inspiratory and expiratory maneuvers. This advancement is anticipated to enhance the diagnostic accuracy of airway inflammation in this demographic, thereby facilitating early diagnosis, precise treatment, and improved management of disease progression.

Detailed description

1. Asthmatic patients and healthy individuals who fulfilled the inclusion criteria were categorized and assigned identification numbers. 2. The basic demographic and health-related information of the subjects was documented, including age, sex, height, weight, respiratory symptoms, medical history, allergy history, disease diagnosis, comorbidities, medication history, smoking history, lung function test results, and other relevant examinations. 3. Pre-testing requirements and preparations included: * Abstaining from all medications (including glucocorticoids, type II inflammatory monoclonal antibodies, leukotriene receptor antagonists, antihistamines, decongestants, hypertonic saline, bronchoconstrictor/diastolic agents, NO synthase inhibitors, and NO donor drugs such as nitroglycerin or L-arginine) for a duration of six hours prior to the test; * Fasting for three hours before the test; * Avoiding all forms of liquid intake (including alcohol and coffee), smoking (both active and passive), strenuous physical activity (such as running or aerobic exercise), and any respiratory diagnostic or therapeutic procedures (including pulmonary function tests and aerosol inhalation) for one hour prior to the test. 4. The researcher verified the subjects' compliance with the aforementioned testing requirements and proceeded with testing for those who met the criteria. Testing was uniformly scheduled during daytime hours. 5. Each participant underwent testing using both the moisture method and the online method, with the order of tests determined randomly via a randomization table to mitigate potential sequential effects. Each test was conducted in accordance with the ATS/ERS Technical Standard for the Determination of Exhaled Nitric Oxide (2005) and the operational guidelines for the equipment. Subjects were instructed to maintain an upright position and to repeat each test three times while in a resting state. A resting period of at least 30 seconds was mandated between tests, provided the subjects experienced no discomfort. The total duration of the testing procedure was anticipated to be approximately 20 minutes per individual.

Conditions

Interventions

TypeNameDescription
DIAGNOSTIC_TESTChemiluminescent FeNO AnalyzerA novel chemiluminescence FeNO Analyzer has been developed, capable of measuring both FeNO50 and FeNO during tidal breathing. Each participant underwent three testing sessions, with the results averaged, and the sequence of tests was randomized.
DIAGNOSTIC_TESTElectrochemical FeNO AnalyzerElectrochemical FeNO analyzers are employed in clinical settings for the measurement of FeNO50. Each participant underwent three testing sessions, with the results averaged, and the sequence of tests was randomized.

Timeline

Start date
2024-09-12
Primary completion
2025-05-30
Completion
2025-09-01
First posted
2025-02-28
Last updated
2025-02-28

Locations

2 sites across 1 country: China

Source: ClinicalTrials.gov record NCT06852911. Inclusion in this directory is not an endorsement.