Trials / Completed
CompletedNCT06851546
Efficacy of Selective Laser Trabeculoplasty Targeting Nasal Versus Inferior 180-degree
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 13 (actual)
- Sponsor
- Mayo Clinic · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
The purpose of this study to optimize Selective Laser Trabeculoplasty (SLT) application when used in the management of open angle glaucoma (OAG)
Detailed description
The purpose of this research is to determine the most effective method in using Selective Laser Trabeculoplasty (SLT) for lowering intraocular pressure (IOP) in patients with ocular hypertension or open-angle glaucoma. We will investigate the IOP lowering differences between nasal 180° SLT and inferior 180° SLT,. The second stage will assess the effect of repeating SLT in the opposite 180° sector after 3 months.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | Nasal 180° Selective Laser Trabeculoplasty (SLT) | The Nasal 180° Selective Laser Trabeculoplasty (SLT) will be performed on the right eye. As per standard procedure, the laser will initially be set at 0.8 mJ (or 0.4 mJ for heavily pigmented TM). The energy level will then be adjusted in 0.1 mJ increments: increased until micro-bubble formation is observed or decreased if bubbles are noted. The desired endpoint is the production of a few fine 'champagne bubbles' every 2-3 laser spots. Larger gas bubbles and trabecular meshwork blanching will require the operator to titrate the power downwards in 0.1 mJ increments. Prophylactic IOP lowering and anti-inflammatory drops will be left to physician preference. |
| PROCEDURE | Inferior 180° Selective Laser Trabeculoplasty (SLT) | The Inferior 180° Selective Laser Trabeculoplasty (SLT) will be performed on the right eye. As per standard procedure, the laser will initially be set at 0.8 mJ (or 0.4 mJ for heavily pigmented TM). The energy level will then be adjusted in 0.1 mJ increments: increased until micro-bubble formation is observed or decreased if bubbles are noted. The desired endpoint is the production of a few fine 'champagne bubbles' every 2-3 laser spots. Larger gas bubbles and trabecular meshwork blanching will require the operator to titrate the power downwards in 0.1 mJ increments. Prophylactic IOP lowering and anti-inflammatory drops will be left to physician preference. |
Timeline
- Start date
- 2025-01-06
- Primary completion
- 2025-11-10
- Completion
- 2025-11-10
- First posted
- 2025-02-28
- Last updated
- 2026-01-07
Locations
2 sites across 2 countries: United States, Canada
Source: ClinicalTrials.gov record NCT06851546. Inclusion in this directory is not an endorsement.