Clinical Trials Directory

Trials / Recruiting

RecruitingNCT06808724

Clinical Influence of Different Surface Treatments on Implant Stabiity

Clinical Influence of Different Surface Treatments on Implant Stabiity: a Prospective Observational Clinical Study

Status
Recruiting
Phase
Study type
Observational
Enrollment
32 (estimated)
Sponsor
International Piezosurgery Academy · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The goal of this observational study is to monitor, within a cohort of patients requiring rehabilitation at two different sites in the premolar area, the primary and secondary stability of implants placed with different surface treatments: vacuum-plasma activation, ozonated oil and non-activated implants.

Detailed description

The primary outcome measures included primary implant stability, assessed through insertion torque and the Implant Stability Quotient (ISQ). Secondary outcome measures included the pattern of implant secondary stability during the first 90 days post-implant placement (ISQ), implant survival after one year, NPRS comparison between treatments at one week postoperatively, and any complications or adverse events. As an additional objective, the study aimed to assess whether a relationship existed between implant surface treatment and early marginal bone loss. Marginal bone levels were measured at three time points: immediately after surgery (T0), upon delivery of prosthetic rehabilitation (T1), and after one year of loading (T2). The distance between the implant platform and the bone crest was measured at each interval, on both the mesial and distal aspects of the implant. A positive value was assigned when the bone crest was coronal to the implant platform, whereas a negative value was assigned when the bone crest was apical to the implant platform. Study Design: Observational, prospective, non-profit case-control study. Study Population: The study will be conducted in an outpatient hospital setting. Enrollment Procedure: All patients meeting the inclusion and exclusion criteria will be enrolled in the study after receiving the Information Sheet and providing written informed consent. Patients seeking implant-supported rehabilitation due to the absence of at least two teeth were initially evaluated with a periapical radiograph of the selected sites to assess residual bone height adequacy. If sufficient bone height was observed, a second-level radiographic examination using Cone Beam Computed Tomography (CBCT) was performed to confirm the adequacy of bone volume for implant rehabilitation. Surgical Phase: Following local anesthesia (mepivacaine HCl 2% with epinephrine 1:100,000), a minimally invasive full-thickness flap was elevated. The same surgeon performed all procedures. Implant site preparation was performed using twist drills. In one group, ozonated oil (Surgy O3, Biosanity) was applied to the implant surface and then the implant was inserted into the prepared osteotomy site. A transepithelial abutment was then attached using a torque wrench, tightened to 30 Ncm. In the second group, implant underwent vacuum-plasma activation immediately before insertion (Plasma X Motion, Megagen, Gyeongbuk, South Korea) and then it was inserted into the prepared osteotomy site. A transepithelial abutment was then attached using a torque wrench, tightened to 30 Ncm. In the control group, the implant was inserted without any treatment. A transepithelial abutment was then attached using a torque wrench, tightened to 30 Ncm. Single monofilament synthetic polypropylene 4.0 sutures were used to close the flaps. A postoperative radiographic assessment was conducted to verify correct implant positioning. A blinded operator measured ISQ values for each implant in two directions: vestibular-palatal and mesio-distal. Measurements were taken at the abutment level three times per direction, and the averages were used for statistical analysis. ISQ measurements were performed using a Resonance Frequency Analysis (RFA) device (Osstell, Göteborg, Sweden) with the appropriate transducer for the selected abutment (Smartpeg Type 05, Osstell, Göteborg, Sweden). Follow-up: After surgery, a follow-up visit was scheduled after one week for suture removal, soft tissue healing assessment, and ISQ measurements. Additional follow-ups occurred at 14, 21, 28, 42, 56, and 90 days, with the same parameters reassessed at each visit. All implants were restored with screw-retained single metal-ceramic crowns four months after surgery and were followed up for at least 12 months after prosthetic loading. Radiographic check-ups were conducted at 6 months and 1 year. For the sample size calculation, it was assumed that the minimal clinically relevant difference between the groups was 5 points on the ISQ scale, with a standard deviation of 5. Using an 80% power and a 95% significance level, the calculation yielded a sample size of approximately 16 participants per group (rounded to the next whole number). This ensures sufficient power to detect the anticipated difference between the groups. Statistical Plan: Statistical analysis will be performed using a computerized statistical package (SigmaStat 3.5, SPSS Inc., Germany). Data will be expressed as mean ± standard deviation or median (interquartile range) for parametric and non-parametric values, respectively.

Conditions

Interventions

TypeNameDescription
PROCEDUREimplant with ozonated oilFollowing local anesthesia (mepivacaine HCl 2% with epinephrine 1:100,000), a minimally invasive full-thickness flap will be elevated. Implant site preparation will be performed with twist drills. Ozonated oil (Surgy O3) will be applied to the implant surface and then the implant will be inserted into the prepared osteotomy site. A 3 mm high transepithelial abutment will be then screwed using a torque wrench, tightened to 30 Ncm. Single monofilament synthetic polypropylene 4.0 sutures will be used to close the flaps.
PROCEDUREnon-activated implantFollowing local anesthesia (mepivacaine HCl 2% with epinephrine 1:100,000), a minimally invasive full-thickness flap will be elevated. Implant site preparation will be performed with twist drills. In the control group, the implant will be inserted without any treatment. A 3 mm high transepithelial abutment will be then attached using a torque wrench, tightened to 30 Ncm. Single monofilament synthetic polypropylene 4.0 sutures will be used to close the flaps.
PROCEDUREimplant with plasma activationFollowing local anesthesia (mepivacaine HCl 2% with epinephrine 1:100,000), a minimally invasive full-thickness flap will be elevated. Implant site preparation will be performed with twist drills. Implant will undergo vacuum-plasma activation immediately before insertion (Plasma X Motion, Megagen, Gyeongbuk, South Korea) and then it will be inserted into the prepared osteotomy site. A transepithelial abutment will then be attached using a torque wrench, tightened to 30 Ncm. Single monofilament synthetic polypropylene 4.0 sutures will be used to close the flaps.

Timeline

Start date
2025-01-31
Primary completion
2025-12-31
Completion
2030-12-31
First posted
2025-02-05
Last updated
2025-02-05

Locations

1 site across 1 country: Italy

Source: ClinicalTrials.gov record NCT06808724. Inclusion in this directory is not an endorsement.