Clinical Trials Directory

Trials / Completed

CompletedNCT06650475

"Optic Nerve Sheath Diameter; Low vs. Conventional Insufflation Pressures''

Evaluation of the Optic Nerve Sheath Diameter in Children Undergoing Laparoscopic Abdominal Surgery at Low and Standard Gas Insufflation Pressures

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
30 (actual)
Sponsor
Konya City Hospital · Academic / Other
Sex
All
Age
2 Years – 17 Years
Healthy volunteers
Accepted

Summary

Objective: This study investigates the impact of carbon dioxide (CO2) pneumoperitoneum on optic nerve sheath diameter (ONSD) and intracranial pressure (ICP) in patients undergoing total laparoscopic hysterectomy. Previous research suggests that pneumoperitoneum can lead to elevated ICP, with the standard intracranial monitoring technique being invasive intraventricular catheter placement. In contrast, bedside ultrasound assessment of ONSD offers a noninvasive alternative for detecting increased ICP. Methods: The Hypothesize will be standard gas insufflation pressure significantly increases ONSD, while low-pressure insufflation will maintain ONSD levels. The primary aim is to compare ONSD variations pre- and post-CO2 insufflation in patients subjected to both low-pressure and standard-pressure laparoscopic surgery. Secondary aims include evaluating end-tidal CO2 measurements between the two groups.

Detailed description

It has been shown in many studies that pneumoperitoneum containing carbon dioxide (CO2) during laparoscopy increases intracranial pressure (ICP). (1) Evaluation of the Effect of Intraabdominal Pressure on Optic Nerve Sheath Diameter in Patients Undergoing Total Laparoscopic Hysterectomy. The standard technique for monitoring ICP is the placement of an intraventricular catheter connected to an external pressure transducer. (2) Bedside evaluation of optic nerve sheath diameter (ONSD) with ultrasound technique is a more practical and noninvasive method used to determine high ICP (\>20 mmHg). The anatomical continuity of the dura with the optic nerve sheath (ONSD) allows the use of this technology, and thus an increase in ICP can be transmitted from the subarachnoid space to the ONSD. (3) Low-pressure pneumoperitoneum reduces analgesic consumption after laparoscopic cholecystectomy in studies, but the effect of standard and low intraabdominal pressures on ICP has not yet been clarified. (4) In our thesis, assuming that standard gas insufflation pressure will increase ONSD, but low gas insufflation pressure will not cause a change, the primary aim was to compare ONSD between two groups of low-pressure and standard-pressure laparoscopic surgery before and after CO2 insufflation preoperatively. Second, the end-tidal CO2 measurements between the two groups will be evaluated.

Conditions

Interventions

TypeNameDescription
PROCEDUREUsing low or standart pressureWritten consent will be obtained before the randomized study. Randomization will be done on the computer using a software program. Participants will be divided into two groups. Patients in Group S will undergo laparoscopy under standard pressures (12-16 mmHg) in laparoscopic surgery, while patients in Group L will undergo laparoscopy under low pressure (8-10 mm Hg).

Timeline

Start date
2024-10-21
Primary completion
2025-01-05
Completion
2025-01-10
First posted
2024-10-21
Last updated
2025-01-30

Locations

2 sites across 1 country: Turkey (Türkiye)

Source: ClinicalTrials.gov record NCT06650475. Inclusion in this directory is not an endorsement.