Trials / Not Yet Recruiting
Not Yet RecruitingNCT06519383
Comparison Of Implant Position Achieved With Fully Guided Versus Partially Guided Implant Placement
Comparative Evaluation Of Accuracy Of Implant Position Achieved With Static Computer Assisted Fully Guided Implant Placement (sCAIP) And Conventional Cast Based Partially Guided Implant Placement (cPGIP)
- Status
- Not Yet Recruiting
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 20 (estimated)
- Sponsor
- Krishnadevaraya College of Dental Sciences & Hospital · Academic / Other
- Sex
- All
- Age
- 18 Years – 80 Years
- Healthy volunteers
- Accepted
Summary
Globally implant therapy is currently accepted as a predictable, viable and successful option to replace missing teeth. Ample studies have shown excellent survival and clinical success rates of dental implants for various indications.The correct three-dimensional (3D) positioning of an implant is considered a prerequisite for an optimal outcome.Computer assisted implant surgery maybe beneficial in patients with limited bone and proximity to anatomic structures.Therefore, the aim of this randomized controlled clinical trial is to investigate the accuracy of implant position achieved with static CAIP(Computer Assisted Implant Placement) and to compare this with the accuracy of conventional cast based partially guided implant placement(cPGIP).
Detailed description
Globally implant therapy is currently accepted as a predictable, viable and successful option to replace missing teeth.As a result, the focus in contemporary implant dentistry has shifted towards the optimization of treatment concepts with aesthetics and function as an important outcome parameter.In this respect, implant installation should be prosthetically -driven, at the same time taking into account anatomical limitations as well as restrictions in terms of bone availability. Apart from aesthetics, a correct implant position may reduce biological and technical complications, favourable esthetic and prosthetic outcome, long term stability of peri-implant tissues, optimal occlusal contacts and implant loading. One possible tool that may facilitate a more accurate implant positioning is guided implant surgery.Virtual implant planning facilitates desired inter implant distance and depth. A top down planning wherein digital images of the edentulous area and mock wax up of the prosthesis is superimposed, allows precise implant placement planning. This digital planning can be converted into a surgical/virtual guide via a 3D printer or a milling machine.Fully guided surgery is based on a surgical guide which will assist the clinician in every step of the surgery starting from the first drill to the implant placement through the use of guiding sleeves in the guide. A partially-guided protocol differs only in the final step: after guided preparation of the osteotomy, the guide is removed and the implant is installed free-handedly.Therefore, the aim of this randomized controlled clinical trial is to investigate the accuracy of implant position achieved with static CAIP(Computer Assisted Implant Placement) and to compare this with the accuracy of conventional cast based partially guided implant placement(cPGIP).
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | guided implant surgery | Surgical guide is fabricated and fitted onto the patient's arch and implant is placed with guide in place. |
Timeline
- Start date
- 2024-07-01
- Primary completion
- 2025-08-01
- Completion
- 2025-08-01
- First posted
- 2024-07-25
- Last updated
- 2024-07-25
Source: ClinicalTrials.gov record NCT06519383. Inclusion in this directory is not an endorsement.