Trials / Completed
CompletedNCT06449183
VIDAS® TBI Real Life Performance in Subjects With Mild Traumatic Brain Injury (mTBI)
Real-life Performance and Added Value of the VIDAS® TBI Blood Test in the Assessment of Mild Traumatic Brain Injury (mTBI), in Subjects With a Glasgow Coma Scale (GCS) Between 13-15
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 903 (actual)
- Sponsor
- BioMérieux · Industry
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
Decision Rules for an initial CT-scan in patients arriving to Emergency Department (ED) and presenting a mild traumatic brain injury could be optimized by the use of an objective parameter easily and rapidly measured. This may be the place for serum biomarkers providing a quick and accurate assessment. BioMérieux has now developed an automated assay for the measurement of serum Glial Fibrillary Acidic Protein (GFAP) and Ubiquitin C-terminal Hydrolase (UCH-L1), the VIDAS® TBI assay to fill out this unmet needs. The goal of the herein study is to generate real-world data and evidences to support the VIDAS® TBI performances.
Detailed description
The assessment of severity of TBI patients is based on the Glasgow Coma Scale (GCS) and the initial management in the ED includes performing a non-contrast brain Computed Tomography (CT) scan if the patient meets specific conditions. To date, real world data show that EDs would actually not follow guideline recommendations and a substantial CT overuse is observed. Management strategies are becoming more and more focused on selective CT use to effectively manage health care resources. Efforts have been made to optimize the indications for brain CT scan after mTBI. Although brain CT scan plays a central role after mTBI, there is an unmet clinical need for an objective tool to optimize indications for CT scan, reduce patient radiation exposure, and possibly predict patient outcome. Clinical Decision Rules for an initial CT-scan could be optimized by the use of an objective parameter easily and rapidly measured. This may be the place for serum biomarkers providing a quick and accurate assessment. BioMérieux has now developed an automated assay for the measurement of serum Glial Fibrillary Acidic Protein (GFAP) and Ubiquitin C-terminal Hydrolase (UCH-L1), the VIDAS® TBI assay to fill out this unmet needs. The goal of the herein study is to generate real-world data and evidences to support the VIDAS® TBI performances.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DIAGNOSTIC_TEST | VIDAS® TBI Test [GFAP and UCH-L1 assays] | The VIDAS® TBI (GFAP, UCH-L1) test is composed of two automated assays - VIDAS® TBI (GFAP) and VIDAS® TBI (UCH-L1) - to be used on the VIDAS® family of instruments for the quantitative measurement of Glial 15 Fibrillary Acidic Protein (GFAP) and Ubiquitin C-terminal Hydrolase- L1 (UCH-L1) in human serum using the Enzyme Linked Fluorescent Assay (ELFA) technique. The results of both assays are required to obtain an overall qualitative test interpretation. |
Timeline
- Start date
- 2024-05-16
- Primary completion
- 2025-09-03
- Completion
- 2025-11-12
- First posted
- 2024-06-07
- Last updated
- 2026-03-06
Locations
5 sites across 1 country: United States
Regulatory
- FDA-regulated device study
Source: ClinicalTrials.gov record NCT06449183. Inclusion in this directory is not an endorsement.