Clinical Trials Directory

Trials / Completed

CompletedNCT06445426

Cystometry Using a Novel Microsensor System in Patients With Neurogenic Bladder Dysfunction

Status
Completed
Phase
Study type
Observational
Enrollment
33 (actual)
Sponsor
Sunnaas Rehabilitation Hospital · Academic / Other
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Not accepted

Summary

The aim of this study is to assess the feasibility and safety of a novel system for percutaneous measurement of bladder pressure. This system enables minimally invasive procedures and high-quality recordings, offering a sampling rate and synchronization surpassing traditional methods. The pressure sensor system has the potential to be developed into a low-cost method suitable for mass production. The study will include a sample of convenience of up to 40 subjects. Pressure will be recorded simultaneously in the bladder using both the conventional and novel pressure recording systems. This simultaneous recording method will provide a direct comparison of pressure recordings between the two systems. Subjects will be examined for any subjective or objective adverse events.

Detailed description

The aim of this study is to assess the feasibility and safety of a novel system for measurement of bladder pressure. The system facilitates a minimally invasive procedure, enabling high-quality recordings with a sampling rate and synchronization that surpass conventional standards. The pressure sensor system has potential to be developed into a low-cost method with mass production. In patients with spinal cord injury and neurogenic bladder dysfunction, measurement of pressure in the bladder (cystometry) is mandatory to evaluate risk factors and assess treatment options. This novel system consists of a micro electro mechanical system (MEMS) integrated in a hollow flexible tube made out of biocompatible material. Recording from this sensor catheter is transmitted to specialized electronic and digital devices for processing. Due to a sensor catheter with a diameter less than 1.0 mm, it is possible to perform transurethral cystometry using a simple minimally invasive technique. The study goal is to compare the simultaneous measurement of the conventional water perfused system compared to a novel pressure sensor system during cystometry. produce high-quality recordings with a higher than conventional sampling rate. The study will include a sample of convenience of up to 40 subjects. The pressure will be recorded simultaneously with the conventional and novel pressure recording system in the urinary bladder. The simultaneous recording with the novel and the conventional method will provide a direct comparison of simultaneous recording of pressure between the two systems. Patients will be examined for subjective or objective adverse events. The sample size is too small for comparison of validity of the two methods in clinical practice. However, the study should be able to conclude on reliability. Thus, pressure measurements will be assessed with both methods during cystometry in up to 40 subjects. Given the technical specifications, the measurements are expected to be nearly identical, thereby ensuring reliability. The study is not intended to provide conclusive results on the comparison between conventional water perfused recording and the novel MEMS pressure system. However, results from this initial study will be the basis for further studies with sufficient power to validate conventional versus novel MEMS technique.

Conditions

Interventions

TypeNameDescription
DEVICECystometryThe procedure will be done according to the International Continence Society's (ICS) recommended indications for the procedure. The investigational device is inserted into a 12F single-use hydrophilic catheter. After correct positioning is verified by ultrasound and x-ray, the investigational device is released from the insertion catheter. The insertion catheter is then carefully removed, securing the correct positioning of the investigational device inside the bladder. The investigational device is connected to a data logger. In the conventional device, the intravesical pressure is recorded using a water perfused 3F catheter with a 3 ml/hour perfusion rate. The 3F catheter is hooked on an 8F catheter to facilitate introduction into the bladder. The catheters used for pressure transmission are connected to external transducers and a computer with software processing the recording

Timeline

Start date
2022-06-01
Primary completion
2023-10-31
Completion
2023-12-31
First posted
2024-06-06
Last updated
2024-06-14

Locations

1 site across 1 country: Norway

Source: ClinicalTrials.gov record NCT06445426. Inclusion in this directory is not an endorsement.