Clinical Trials Directory

Trials / Completed

CompletedNCT06434142

Wear Assessment of Novel PEEK Telescopic Attachment for Overdenture

Wear Assessment of Novel PEEK Telescopic Attachment for Implant Retained Mandibular Overdenture

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
20 (actual)
Sponsor
Hamada Zaki Mahross Atia · Academic / Other
Sex
Male
Age
50 Years – 70 Years
Healthy volunteers
Accepted

Summary

To assess the wear of Zirconia-PEEK versus cobalt-chromium-PEEK telescopic attachments for implant retained complete mandibular overdenture. The wear of Zirconia-PEEK telescopic attachments can affect the retention of implant retained complete mandibular overdenture.

Detailed description

Twelve completely edentulous patients were randomly chosen for implant retained telescopic overdentures construction and divided into two groups, where group I was a patient with zirconia copy, and group II was with cobalt chromium CoCr copy. The PEEK was constructed for both groups as a secondary coping telescopic attachment for the denture. The wear measurements of PEEK were performed optically by using a USB digital microscope with a built-in camera connected to a compatible personal computer at different intervals of baseline, 3, 6, and 9 months. The data was statistically analyzed and compared using student t-test, ANOVA, and Post Hoc Test.

Conditions

Interventions

TypeNameDescription
PROCEDUREimplant overdentureFollowing the two-stage surgical protocol, two dental implant fixtures with a length of 10 mm and a diameter of 3.7 mm were inserted at the canine area of the mandibular alveolar ridge.

Timeline

Start date
2024-02-11
Primary completion
2024-04-20
Completion
2024-05-01
First posted
2024-05-30
Last updated
2024-05-30

Locations

1 site across 1 country: Egypt

Source: ClinicalTrials.gov record NCT06434142. Inclusion in this directory is not an endorsement.