Trials / Recruiting
RecruitingNCT06425614
COmbined pLaTelet and eRythrocyte AutotransfusioN During Cardiac surgEry (COLTRANE) Trial
Centrifugation-based Versus Filtration-based Intraoperative Cell Salvage on Quality of Perioperative Haemostasis in Cardiac Surgery: A Randomized Clinical Trial
- Status
- Recruiting
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 570 (estimated)
- Sponsor
- University Hospital, Bordeaux · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
Despite significant advances in patient blood management, cardiac surgery remains a surgical procedure at high risk for bleeding. Numerous perioperative blood conservation strategies have been developed for limiting the use of blood products. Among them, the processing of shed blood and residual cardiopulmonary bypass circuit volume with autotransfusion device is routinely used. Conventional centrifugation-based autotransfusion devices actually available only recover red blood cells while platelets and coagulation factors are almost totally lost. Consequently, large amounts of intraoperative cell salvage could significantly alter perioperative haemostasis. The SAME autotransfusion device (i-SEP, France) is a new and innovative filtration-based autotransfusion device able to recover erythrocytes, leukocytes but also platelets. By offering the opportunity to re-infuse to patients their own platelets in addition red blood cells, significantly improve perioperative haemostasis with this new device is expected. The purpose of the COLTRANE trial is to compare the quality of the perioperative haemostasis in cardiac surgical patients for whom intraoperative cell salvage will be performed using either the SAME autotransfusion device or conventional centrifugation-based device. Because allogenic transfusion of blood products as well as surgical re-exploration for excessive bleeding are associated with poor outcomes and prolonged length of stay, the use of filtration-based SAME device by maintaining perioperative haemostasis could improve outcomes and reduce length of stay of high risk patients. The fact that patients receive their own platelets should also limit the risk of allo-immunization and immunomodulation which is recognized as one of the underlying mechanisms of perioperative increased risk of infection.
Detailed description
The SAME device is a new and innovative filtration-based autotransfusion device able to recover both erythrocytes and platelets. A multicentre single-arm clinical feasibility and safety trial conducted by our group, using SAME device on 50 cardiac surgical patients reported erythrocyte yield per cycle of 89%, post-treatment hematocrit of 43% with an excellent washing performance. In addition, the device recovered 52% of platelets, that were found unaltered by the device as demonstrated by a limited platelet activation and a strong response to thrombin-pathway stimulation assessed by flow cytometry. By offering the opportunity to re-infuse to the patients their own platelets in addition to their RBC, this new device might significantly improve perioperative haemostasis and thus decrease the need for blood products. It is well established that severe postoperative bleeding and blood products transfusion lead to increase morbidity and mortality. Consequently, an improvement of postoperative outcomes and a decrease in intensive care unit (ICU) and hospital length of stay may be expected. The fact that patients receive their own platelets should limit the risk of allo-immunization and immunomodulation which is recognized as one of the underlying mechanisms of perioperative increased risk of infection. Consequently, a reduction of infectious complication may be also expected. The purpose of COLTRANE trial is to test the hypothesis that the intraoperative use of the filtration-based SAME autotransfusion device could improve perioperative haemostasis thereby reducing the proportion of patients exhibiting clinically significant perioperative bleeding (moderate to massive bleeding according the Universal Definition of Perioperative Bleeding (UDPB) classification).
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | Autotransfusion | ANTIFIBRINOLYTIC THERAPY : tranexamic acid as antifibrinolytic therapy : dose after anaesthesia induction followed by continuous intravenous infusion until end INTRAOPERATIVE MANAGEMENT : * Routine monitoring : five lead-ECG, pulse oximeter, non-invasive arterial pressure will be instituted. A peripheral venous catheter and an arterial catheter * The general anaesthesia : * propofol and Remifentanil or sufentanil both simultaneously administered . * monitoring of the bispectral index * Triple lumen central venous catheter * Heparinization (300 UI/kg) * Aortic and right auricular cannulations TRANSFUSION PROTOCOL : * During CPB, PRBC transfusion if necessary * In the postoperative period if necessary In bleeding patients: The perioperative use of blood products will be managed according to results of conventional haemostasis tests or viscoelastic point of care tests when available in the center. |
Timeline
- Start date
- 2024-07-15
- Primary completion
- 2026-02-15
- Completion
- 2026-02-15
- First posted
- 2024-05-22
- Last updated
- 2025-06-29
Locations
10 sites across 1 country: France
Source: ClinicalTrials.gov record NCT06425614. Inclusion in this directory is not an endorsement.