Clinical Trials Directory

Trials / Completed

CompletedNCT06423742

Consecutive Dual-Session tDCS in Chronic Subjective Severe to Catastrophic Tinnitus With Normal Hearing

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
42 (actual)
Sponsor
Dongtan Sacred Heart Hospital · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Accepted

Summary

We aimed to analyze the effect of continuous dual session tDCS in patients with severe chronic subjective tinnitus without any evidence of hearing loss in terms of relief of tinnitus perception, distress, and loudness. Also, we investigated the difference in the maintenance duration of the tinnitus suppression effect of consecutive dual session tDCS compared to other groups followed up for 2 months.

Detailed description

The participants were randomly allocated with three different arms (control, single-session, and dual session) using block to balance the size of each group. Pure tone audiometry, speech audiometry, tinnitogram (pitch matching, loudness, minimal masking level and residual inhibition), auditory evoked potential, THI, visual analogue scale (VAS) of loudness, awareness and annoyance, and BDI were evaluated as a baseline tests. Participants who assigned to the control group underwent dual sham stimulation per day, twice a week for 1 month. Patients were received sham and true stimulation once alternately in the single session group and two true stimulation per day in the dual session group for the same period as the control group. All subjects who enrolled this study were given a conventional treatment such as tinnitus retraining therapy, sound therapy using sound generator, and medications like clonazepam, selective serotonin reuptake inhibitors for patients who wanted to take for relief of symptoms.

Conditions

Interventions

TypeNameDescription
DEVICETranscranial direct current stimulationThe device used for tDCS in this study was DC-Stimulator Plus (NeuroConn GmbH, Ilmenau, Germany). The localization of stimulation area (DLPFC) was determined according to the 10/20 EEG system. Non-conducting, elastic head strap was placed around the head to prevent displacement during stimulation. The recording electrode covered with 5 x 7 cm sized traditional rectangular sponge was soaked with 6-7 mL of 0.9% NaCl saline solution per side and placed on the F3 (anode, left frontal) and F4 (cathode, right frontal) EEG location. Subjects were given 2 mA stimulation intensity for 20 min per session including fade-in and fade-out times for 20 seconds each. Interval between each session was 20 min. Sham procedure has been adopted a Fade In of current, Short Stimulation, Fade Out (FISSFO) protocol that consist of initial ramp up for 20 seconds, 2 mA stimulation for 40 seconds, and 20 seconds for ramp down. To check to impendence, brief current of 110 µA over 15ms every 550ms was delivered.

Timeline

Start date
2021-12-15
Primary completion
2022-09-30
Completion
2022-09-30
First posted
2024-05-21
Last updated
2024-05-21

Locations

1 site across 1 country: South Korea

Source: ClinicalTrials.gov record NCT06423742. Inclusion in this directory is not an endorsement.