Clinical Trials Directory

Trials / Completed

CompletedNCT06422325

Two Way Crossover Closed Loop Study Insulin vs Insulin and Pramlintide

A Crossover Study to Evaluate Insulin/Pramlintide Versus Insulin Alone Delivery Strategy

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
33 (actual)
Sponsor
Oregon Health and Science University · Academic / Other
Sex
All
Age
18 Years – 70 Years
Healthy volunteers
Not accepted

Summary

The purpose of this study is to test how well a new investigational closed loop system manages your blood sugar with the ability to deliver insulin and pramlintide. Pramlintide is a drug that is used with mealtime insulin to control blood sugar in people who have diabetes. It works by slowing down the movement of food through the stomach which prevents blood sugar from rising too high after a meal. The closed loop system will receive glucose values from the Dexcom G6 continuous glucose monitoring (CGM) and automatically send commands to one Omnipod for insulin and one Omnipod for pramlintide delivery.

Detailed description

Participants will undergo two 12.5 hour clinic visits. Participants will complete a training on how to start the Dexcom G6 sensor at home. Participants will start the G6 sensor the day before each study visit. For one visit, the system will use insulin only for managing blood sugar. For the other study, the system will use both insulin and pramlintide. The order of the visits will be randomly chosen. For 3 days before the insulin and pramlintide visit, participants will dose with pramlintide before each meal. During the visits, participants will wear one or two Omnipods to delivery insulin and insulin/pramlintide and a Dexcom G6 CGM. The CGM system will provide sensor glucose data every 5 minutes. Sensor glucose data will be wirelessly transmitted via Bluetooth Low Energy (BTLE) from the Dexcom G6 to the smartphone master controller every 5 minutes. The smartphone will communicate via BTLE to an Omnipod for insulin delivery. The closed loop system will receive activity data through a Polar M600 watch worn by the participant. Participants will eat breakfast and lunch in clinic.

Conditions

Interventions

TypeNameDescription
DEVICEMPC closed-loop system in insulin only modeThe Model Predictive Control (MPC) insulin infusion algorithm contains a model within the controller that takes as an input the aerobic metabolic expenditure in addition to the CGM and meal in puts. The algorithm uses heart rate and accelerometer data collected on the patient's body to calculate metabolic expenditure (METs). The METs then acts on the model for the insulin dynamics, whereby more energy expenditure and longer duration exercise can lead to a more substantial effect of insulin on the CGM. The MPC also has missed meal insulin bolus detection where the system will calculate the amount of insulin that was missed for a meal. The missed meal boluses can be delivered automatically without any input from the user. This feature can also be disabled. The device in this mode will administer insulin continuously for managing blood sugar.
DEVICEMPC closed-loop system in insulin/pramlintide modeThe Model Predictive Control (MPC) insulin infusion algorithm contains a model within the controller that takes as an input the aerobic metabolic expenditure in addition to the CGM and meal in puts. The algorithm uses heart rate and accelerometer data collected on the patient's body to calculate metabolic expenditure (METs). The METs then acts on the model for the insulin dynamics, whereby more energy expenditure and longer duration exercise can lead to a more substantial effect of insulin on the CGM. The MPC also has missed meal insulin bolus detection where the system will calculate the amount of insulin that was missed for a meal. The missed meal boluses can be delivered automatically without any input from the user. This feature can also be disabled. The device in this mode will administer both insulin and pramlintide continuously for managing blood sugar. The system will deliver pramlintide in a fixed ratio to insulin at 6 mcg of pramlintide delivered for every 1 unit of insulin.

Timeline

Start date
2024-07-12
Primary completion
2025-01-04
Completion
2025-01-28
First posted
2024-05-20
Last updated
2026-03-05
Results posted
2026-03-05

Locations

1 site across 1 country: United States

Regulatory

Source: ClinicalTrials.gov record NCT06422325. Inclusion in this directory is not an endorsement.