Clinical Trials Directory

Trials / Unknown

UnknownNCT06381310

Ultrasound-guided Cannulation of Difficult Hemodialysis Arteriovenous Access

Ultrasound-guided Cannulation of Difficult Hemodialysis Arteriovenous Access: A Randomized Controlled Trial

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
50 (estimated)
Sponsor
National Taiwan University Hospital · Academic / Other
Sex
All
Age
20 Years – 90 Years
Healthy volunteers
Accepted

Summary

Patients with ESRD are able to maintain life by undergoing renal replacement therapy, including hemodialysis (HD), peritoneal dialysis (PD) or kidney transplantation. HD continues to be the primary option. Arteriovenous fistula (AVF) and arteriovenous graft (AVG) are the common access sites for hemodialysis (HD) patients. AVF is the best access for dialysis , which is known as the lifeline of hemodialysis patients, but requires 6 to 8 weeks to maturate. Long-term use of an AVF for dialysis requires the ability of the dialysis staff to cannulate it successfully with large-bore needles thrice weekly. With increasing AVF prevalence as well as aging and more obese populations in the developed world, increasing numbers of difficult-to-cannulate AVFs are being encountered in practice. Traditionally, after maturation, cannulation of new AVF/AVG was performed by trained renal nurses through physical examination, namely listening to bruits and feeling for thrills to guide needle placement, known as "blind" cannulatio. However, physical examination is not reliable for first and difficult access cannulation (e.g., small or partial stenosis, deep-seated AVF/AVG, presence of clots, after multiple failed attempts with hematoma /swelling, and/or immature access with small vessel caliber), rendered higher rate of cannulation failure and lower AVF and AVG survival. Unfortunately, cannulation failure result in access damage, vessel intimal lining damage leading to stenosis, thrombosis, or aneurysm formation contributing to AVF failure, treatment delay and increased requirement for central venous access devices (CVAD). Patients with early AVF failure have much higher mortality risk, particularly if they are older and female. Van Loon et al. revealed that up to 90% of the first cannulation had complications (i.e., infiltration including hematoma formation and missed cannulation). With a high rate of AVF maturation failure (38-60%) in general, cannulation failure may be avoidable if a more in-depth assessment was done before the attempt. Ultrasound (US) guided cannulation effective in identifying access location and patency. Roshan et al. reported a case study on bedside ultrasonography for AVF cannulation. The study showed decreased cannulation failure, vessel wall damage, thrombosis, and hematoma formation risks also reduced missed cannulation and increased staff confidence in performing cannulation. Therefore, this study aims to explore the effects of ultrasound technology on arteriovenous access successful cannulation for patients with end-stage kidney disease to provide reliable research integration evidence as the basis for future clinical care.

Conditions

Interventions

TypeNameDescription
DEVICEasus-handheld-ultrasound LU710LUltrasound-guided group:The nurse uses ultrasound-guide injection. control group: After physical assessment by the nurse, the injection will be carried out according to the conventional injection plan.

Timeline

Start date
2024-02-26
Primary completion
2024-10-30
Completion
2024-10-30
First posted
2024-04-24
Last updated
2024-04-24

Locations

1 site across 1 country: Taiwan

Source: ClinicalTrials.gov record NCT06381310. Inclusion in this directory is not an endorsement.