Clinical Trials Directory

Trials / Recruiting

RecruitingNCT06371729

DEEP Substrate Mapping Versus Activation Mapping for VT

Substrate-based DEEP Mapping Versus Activation Mapping: A Prospective Randomized Multicenter Study

Status
Recruiting
Phase
N/A
Study type
Interventional
Enrollment
222 (estimated)
Sponsor
IRCCS Ospedale San Raffaele · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

Substrate-based DEEP mapping and activation mapping are two of the main techniques used for guiding ventricular tachycardia (VT) ablation. There is no data comparing directly the extent of applicability, procedural results, and the long-term outcomes between the two mapping strategies.This randomized clinical trial aims to test whether activation mapping is superior to DEEP mapping to reduce ventricular tachycardia recurrence. The primary endpoint of the study is to compare recurrence-free survival rate of ventricular tachycardia at 12 months and procedural feasibility of substrate-based DEEP mapping versus activation mapping for VT ablation.

Conditions

Interventions

TypeNameDescription
PROCEDUREDEEP mappingThe Substrate-based DEEP Mapping aims to identify the arrhythmogenic substrate of VT in sinus rhythm (SR). A standardized VT mapping and ablation procedure in SR has been proven effective in reducing VT recurrences in a multicenter setting by targeting late potential (LP) abolition. Regions with LPs and LAVAs that displayed decremental behavior evoked during right ventricular (RV) pacing with extra stimuli (decrement-evoked potential; DEEP), colocalized with the regions of the initiation and diastolic pathway of the VT more accurately than those areas displaying non decremental LPs. Device use for mapping and ablation procedure: FlexAbility/Tactiflex/TactiCath Ablation Catheter Sensor Enabled (Abbott, MN), high-density grid mapping catheter (GMC; Advisor HD Grid Mapping Catheter Sensor Enabled, Abbott, MN)
PROCEDUREActivation MappingVT Activation Mapping can localize reentry circuits, and the diastolic pathway isthmus is the desirable target for ablation when possible because it can eliminate the elements required for reentry. In fact, activation mapping of the entire diastolic pathway is associated with higher freedom from VT recurrences compared to substrate modification Device use for mapping and ablation procedure: FlexAbility/Tactiflex/TactiCath Ablation Catheter Sensor Enabled (Abbott, MN), high-density grid mapping catheter (GMC; Advisor HD Grid Mapping Catheter Sensor Enabled, Abbott, MN)

Timeline

Start date
2024-06-13
Primary completion
2027-06-01
Completion
2027-06-01
First posted
2024-04-17
Last updated
2026-03-27

Locations

1 site across 1 country: Italy

Source: ClinicalTrials.gov record NCT06371729. Inclusion in this directory is not an endorsement.