Clinical Trials Directory

Trials / Completed

CompletedNCT06353724

Comparison Between the Effect of Using Conventional and Digital Oral Positional Radiation Stent

Comparison Between the Effect of Using Conventional and Digital Oral Positional Radiation Stent on Healthy Tissues, Salivary PH

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
16 (actual)
Sponsor
Tanta University · Academic / Other
Sex
All
Age
20 Years – 70 Years
Healthy volunteers
Accepted

Summary

The goal of this clinical trial is to compare between the Effect of Using Conventional and Digital Oral Positional Radiation Stent on Healthy tissues, salivary PH. The main question it aims to answer are: Does the difference in manufacturing method affect on Healthy tissues, salivary PH. Participants will use radiation positioning stent during radiotherapy sessions Two groups will be compared * Group A: OPRS was constructed according to the conventional technique. * Group B: OPRS was constructed digitally using CAD /CAM technology. to evaluate Dosimetric analysis to quantify the radiation dose in OARs, PH of saliva measurement and Mucositis assessment.

Detailed description

This study will be a clinically prospective study that will include 16 patients with head and neck cancer. This study will be carried out at the Clinical Prosthodontics Department \& Clinical Oncology Department of Tanta University. Informed consent will be obtained from all patients with maintenance of their privacy prior to inclusion in the study according to the guidelines on human research adopted by the Research Ethics Committee, Faculty of Dentistry, Tanta University. Patient's evaluation: All patients will be subjected to the following protocol: Oral examination: Clinical dental evaluation, intraoral photography and mouth opening measurements Grouping: The patients will be divided randomly into 2 groups (each group consists of 8 patients) according to the technique that will be used for construction: First group: The OPRS will be constructed according to the conventional technique.27 Second group: The OPRS will be constructed digitally according to the following steps: Intraoral scanning: It will be done using an intraoral scanner to generate three 3D images: the first of the superior arch, the second of the inferior arch, and the third of the maximum habitual intercuspation. Images will be compiled into a 3D file system. Oral positioning radiation stent design: The compiled file will be exported into Exocad software, which is smart software for dental design on digital models, for stent design, and by using a virtual articulator. 3D printing: After optimizing the digital file, 3D printing will be performed. The oral positioning radiation stent will be printed using the 3D printer Resin Printing Material. For both groups: Insertion: making the necessary adjustment will be done. RT techniques and dose distributions: All patients will be referred to the RT department for IMRT planning. During the pre-irradiation simulation, the intraoral stents will be placed, and the patients will be immobilized by individual thermoplastic masks. A computed tomography scan will be conducted to determine the precise planning target volume (PTV); all patients will be scanned using the positional prosthesis once and without it. Dosimetric analysis: To quantify the radiation dose in the structures, the maxilla (area of the teeth), both parotid glands (ipsilateral and contralateral), the mandible, and the PTV will be defined and contoured in computed tomography pre-irradiation planning. The mean corresponding dose of each structure will be acquired using a dose-volume histogram. All patients will complete the radiotherapy sessions using the positional radiation prosthesis together with the extra oral immobilization masks. Mucositis assessment: The severity of mucositis will be assessed weekly from the beginning of RT to the end of the treatment (mean time, 7 weeks). It will be scored in accordance with the classification criteria of the National Cancer Institute. PH of saliva measurement: A saliva sample will be collected from each patient to measure salivary PH by digital PH meter 19 before the beginning of radiotherapy, and the measurement will be continued weekly until the end of the treatment.

Conditions

Interventions

TypeNameDescription
DEVICEconventional oral positioning stent were used during radiation planning and the PTV will be defined and contoured in computed tomography pre irradiation planningDosimetric analysis: the maxilla (area of the teeth), both parotid glands (ipsilateral and contralateral), the mandible, and the PTV were defined and contoured in computed tomography pre irradiation planning. The mean corresponding dose of each structure were acquired using a dose-volume histogram. All patients will complete the radiotherapy sessions using the positional radiation prosthesis. Mucositis assessment: The severity of mucositis will be assessed weekly from the beginning of RT to the end of the treatment (mean time, 7 weeks). It will be scored in accordance with the classification criteria of the National Cancer Institute. PH of saliva measurement: Collection of saliva sample were done from each patient to measure salivary PH by digital PH meter before beginning of radiotherapy and the measurement will be continued weekly till the end of the treatment.
DEVICEDigital positioning stentDigital positioning stent

Timeline

Start date
2019-10-14
Primary completion
2020-10-01
Completion
2021-01-01
First posted
2024-04-09
Last updated
2024-04-09

Locations

1 site across 1 country: Egypt

Source: ClinicalTrials.gov record NCT06353724. Inclusion in this directory is not an endorsement.