Clinical Trials Directory

Trials / Completed

CompletedNCT06276582

Screening for Neonatal Jaundice With a Mobile Health Device: a Validation Study in Oaxaca, Mexico.

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
177 (actual)
Sponsor
Norwegian University of Science and Technology · Academic / Other
Sex
All
Age
1 Day – 14 Days
Healthy volunteers
Not accepted

Summary

The performance and accuracy of the smartphone application (app) Picterus Jaundice Pro (PicterusJP) will be validated by a cross-sectional study conducted in low resource settings in Mexico. Physics-based and machine learning-based models will be used to analyze the images obtained with the app and its performance will be compared.

Detailed description

A cross-sectional prospective study is taken place at Hospital General de Zona 1 in the city of Oaxaca, Mexico. Participants are recruited from the maternity ward and emergency room and data collection is conducted by one experienced pediatrician and one paediatrics' resident. After informed consent is obtained, background data including time and date or birth, birth weight, gestational age, parent's skin type according to Fitzpatrick scale and newborn's skin color according to Neomar's scale is being collected. Visual assessment is performed by the researchers using Kramer's scale. To obtain the bilirubin measurements with the smartphone app Picterus Jaundice Pro (Picterus JP), the calibration card is placed on the newborn's chest and a set of six images, 3 with and 3 without flash, are captured. The smartphones used to capture the images are Samsung A23, iPhone 11 and iPhone 15 Pro. Total serum bilirubin (TSB) levels are measured with a blood sample obtained within one hour of capturing the images and analyzed at the hospital laboratory facilities. Demographic and clinical characteristics will be analyzed by descriptive statistic. Bilirubin measurements correlation between Picterus JP using both models and TSB will be determined by Pearson's correlation coefficient. Systematic over or underestimation of bilirubin levels will be evaluated using Bland-Altman plots. Accuracy measurements will be determined using receiver operating characteristics (ROC) and area under the curve (AUC) analysis. To compare the correlations from both models, Fisher's r to z transformation approach will be applied

Conditions

Interventions

TypeNameDescription
DEVICEScreening for neonatal jaundice with a mobile health devicePicterus Jaundice Pro will be used to screen for neonatal jaundice by taking 6 photos of the newborns skin, where the Picterus calibration card is place.

Timeline

Start date
2023-01-17
Primary completion
2024-06-08
Completion
2024-06-08
First posted
2024-02-26
Last updated
2024-08-12

Locations

1 site across 1 country: Mexico

Source: ClinicalTrials.gov record NCT06276582. Inclusion in this directory is not an endorsement.