Clinical Trials Directory

Trials / Completed

CompletedNCT06271499

The Effect of Using Smart Glasses Integrated Ultrasonography on Radial Artery Catheterization

The Effect of Using Smart Glasses Integrated Ultrasonography on the Success of the Procedure and Comfort of the Anesthesiologist in Radial Artery Catheterization

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
120 (actual)
Sponsor
Ankara University · Academic / Other
Sex
All
Age
18 Years – 90 Years
Healthy volunteers
Not accepted

Summary

The use of Ultrasonography (USG) in arterial catheterization, in which the comfort of the practitioner and hand-eye coordination become very important, is frequently needed by anesthesiologists in their daily practice. The aim of this study is to evaluate the success rate and anesthesiologist's satisfaction between two practitioners with different levels of experience in radial artery catheterization with smart glasses USG.

Detailed description

The arterial catheterizations were usually performed by anesthesiologists in operation rooms and intensive care units for many reasons such as blood pressure monitoring and gas sampling. The choice of radial artery is because of its anatomic advantages. However some patients related features can cause difficulties in catheterization. The use of ultrasounography (USG) guidance raises the rate of success and decreases the complications. Coordination skills between hand, eye, procedure area and screen are essential for the USG-guided catheterization. Smarth glasses, project the USG image in real-time directly in front of the practitioner's eyes and thus allows the practitioner to simultaneously view the screen and the procedure area. The primer aim of this study is to evaluate the success rate and anesthesiologist's satisfaction between two practitioners with different levels of experience in radial artery catheterization with smart glasses USG. The secondary aims are to evaluate the cannulation time and complications between groups. 120 patients \>18 years who would be undergone elective elective surgery with an indication for radial artery catheterization between August 2022 and December 2022 were included to the prospective, randomised, single centre study. Patients underwent radial artery catheterization for any reason in the last one month, and with contraindications for catheterization were excluded. Patients were divided randomly into two groups (Group I: patients underwent radial artery catheterization using standart USG, and Group II: patients underwent radial artery catheterization using smart glasses integrated UGG). The catheterization was performed by two anesthetists with different experience. The subcutaneous distance, radial artery depth and diameter in short axis, cannulation time and ergonomic satisfaction of the practitioners were recorded. The program SPSS 11.5 was used to analyze data.

Conditions

Interventions

TypeNameDescription
OTHERRadial artery catheterization with USGRadial artery catheterization with USG The catheterization was performed by two anesthesiologist with different experience (Junior practitoner who has the experience of 20-50, and the senior practitioner who has the experience of \>50 radial artery catheterizations). The side to be catheterized was determined by modifie Allen test which was first performed on the nondominant hand. After general anesthesia induction, a 45° angle was given to wirst of selected side with a support. After skin asepsis, radial artery was vizualized 2 centimeter (cm) above the wrist in short axis with the high-frequency linear USG probe. The radial artery puncture was performed while step by step monitoring the needle tip in short axis out-of-plane technique. Following the puncture, radial artery catheterized with a 3 French 8 cm catheter.
OTHERRadial artery catheterization with smart glasses integrated UGGThe catheterization was performed by two anesthesiologist with different experience (Junior practitoner who has the experience of 20-50, and the senior practitioner who has the experience of \>50 radial artery catheterizations). Before the study, as practitioners had no previous experience with smart glasses, they performed 5 catheterizations with smart glasses integrated USG on model. The side to be catheterized was determined by modifie Allen test which was first performed on the nondominant hand. After general anesthesia induction, a 45° angle was given to wirst of selected side with a support. After skin asepsis, radial artery was vizualized 2 centimeter (cm) above the wrist in short axis with smart glasses integrated high-frequency linear USG probe. The radial artery puncture was performed while step by step monitoring the needle tip in short axis out-of-plane technique. Following the puncture, radial artery catheterized with a 3 French 8 cm catheter.

Timeline

Start date
2022-08-01
Primary completion
2022-12-28
Completion
2023-02-14
First posted
2024-02-21
Last updated
2024-02-21

Locations

1 site across 1 country: Turkey (Türkiye)

Source: ClinicalTrials.gov record NCT06271499. Inclusion in this directory is not an endorsement.