Clinical Trials Directory

Trials / Recruiting

RecruitingNCT06230458

Fractional Exhaled Nitric Oxide (FeNO)- Test as add-on Test in the Diagnostic Work-up of Asthma

Care Evaluation Study of the Fractional Exhaled Nitric Oxide (FeNO)- Test as add-on Test in the Diagnostic Work-up of Asthma

Status
Recruiting
Phase
N/A
Study type
Interventional
Enrollment
171 (estimated)
Sponsor
Franciscus Gasthuis & Vlietland (Hospital) · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The Global Initiative of Asthma Guideline (GINA) recommends a flowchart to diagnose asthma with first-step spirometry with reversibility and a bronchial challenge test (BPT) with histamine or methacholine as a second step. This multi-center prospective care evaluation study compares the 'standard asthma diagnostic work-up' (spirometry with reversibility and BPT) to the 'new asthma diagnostics work-up' (FeNO-test as an intermediate step between the spirometry with reversibility and the BPT), intending to determine the impact of the FeNO-based strategy, in terms of the number of avoided BPTs, cost-effectiveness and reduced burden to the patient and health care. The cost reduction of incorporating the FeNO-test in the new diagnostic algorithm will be established by the number of theoretically avoided BPT. The decrease in burden will be studied by calculating differences in the Visual Analogue Scale (VAS) -score and Asthma Quality of Life Questionnaire (AQLQ) -score after the BPT and FeNO-test with an independent T-test. The accuracy of the FeNO-test will be calculated by comparing the FeNO-test outcomes to the (gold standard) BPTs outcomes in terms of sensitivity and specificity.

Detailed description

Background Asthma is a common disease characterized by chronic inflammation of the lower airways, bronchial hyperactivity, and (reversible) airway obstruction. The Global Initiative of Asthma Guideline (GINA) recommends a flowchart to diagnose asthma with first-step spirometry with reversibility and a bronchial challenge test (BPT) with histamine or methacholine as a second step. The BPT is considered burdensome, time-consuming for patients and staff, can cause side effects, and is expensive. In addition, this test strongly encumbers lung function capacity. Elevated Nitric Oxide (NO) is associated with airway eosinophilic inflammation in asthma patients and can be measured in exhaled air with the Fractional exhaled (Fe) NO-test. This low-burden FeNO-test could be used as an 'add-on' test in asthma diagnostics. Methods/analysis This multi-center prospective care evaluation study compares the 'standard asthma diagnostic work-up' (spirometry with reversibility and BPT) to the 'new asthma diagnostics work-up' (FeNO-test as an intermediate step between the spirometry with reversibility and the BPT), intending to determine the impact of the FeNO-based strategy, in terms of the number of avoided BPTs, cost-effectiveness and reduced burden to the patient and health care. The accuracy of the FeNO-test is included for verification. The cost reduction of incorporating the FeNO-test in the new diagnostic algorithm will be established by the number of theoretically avoided BPT. The decrease in burden will be studied by calculating differences in the Visual Analogue Scale (VAS) -score and Asthma Quality of Life Questionnaire (AQLQ) -score after the BPT and FeNO-test with an independent T-test. The accuracy of the FeNO-test will be calculated by comparing the FeNO-test outcomes to the (gold standard) BPTs outcomes in terms of sensitivity and specificity.

Conditions

Interventions

TypeNameDescription
DIAGNOSTIC_TESTFeNO-testFractional Exhaled Nitric Oxide (FeNO)- test

Timeline

Start date
2023-10-01
Primary completion
2025-10-01
Completion
2026-10-01
First posted
2024-01-30
Last updated
2024-01-30

Locations

1 site across 1 country: Netherlands

Source: ClinicalTrials.gov record NCT06230458. Inclusion in this directory is not an endorsement.