Clinical Trials Directory

Trials / Unknown

UnknownNCT06224868

Comparison of the Effects of Different PEEP Values With USG on Optic Nerve Sheath Diameter

Comparison of the Effects of Different PEEP Values With USG on Optic Nerve Sheath Diameter (ONSD), Diaphragmatic Thickness ,and Lung Score in Laparoscopic Surgery Patients

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
45 (estimated)
Sponsor
Baskent University · Academic / Other
Sex
All
Age
18 Years – 65 Years
Healthy volunteers
Accepted

Summary

Laparoscopic surgeries are now more popular because of the advantages such as shorter hospital stay, minimal scar. In order to perform laparoscopic surgery, pneumoperitoneum should be initiated. The optic nerve sheath is an extension of the dura mater and the subarachnoid space is continuous with the intracranial subarachnoid space. Therefore, non-invasive monitoring of the increase in intracranial pressure (ICP) can be achieved by measuring the optic nerve and sheath diameter with ultrasound. Since ONSD measurement with ultrasound is an easily applicable technique, it is useful in monitoring intracranial pressure changes based on the optic nerve diameter during intraoperative changes

Detailed description

Laparoscopic surgeries are now becoming increasingly common compared to traditional laparotomies, as they have advantages such as more minimal scarring, shorter hospital stay, fewer complications, and early mobilization. In these surgeries, pneumoperitoneum provided with carbon dioxide (CO2) has many effects on the cardiovascular, pulmonary, renal, metabolic and cerebral systems. Pulmonary compliance and functional residual capacity decrease due to pnemoperitoneum, ventilation/perfusion mismatch occurs, and as a result, hypoxemia may occur. A minimum of 4-6 cm H20 positive end-expiratory pressure (PEEP) should be applied to all intubated patients under general anesthesia to reduce postoperative pulmonary complications (especially atelectasis) and prevent ventilation/perfusion mismatch and hypoxemia. The optic nerve sheath is an extension of the dura mater and the subarachnoid space is continuous with the intracranial subarachnoid space. Therefore, non-invasive monitoring of the increase in intracranial pressure (ICP) can be achieved by measuring the optic nerve and sheath diameter with ultrasound. When ICP is \> 20 mm Hg, measuring the optic nerve sheath diameter (ONSD) between 5.2 and 5.9 mm has a sensitivity of 74-95% and a specificity of 74-100%. Since ONSD measurement with ultrasound is an easily applicable technique, it is useful in monitoring intracranial pressure changes based on the optic nerve diameter during intraoperative changes (trendelenburg/reverse trendelenburg position, pneumoperitoneum , PEEP in mechanical ventilation).

Conditions

Interventions

TypeNameDescription
OTHERinsufflationLaparoscopic surgery begins with intraabdominal placement of the insufflation needle or trochar, followed by carbon dioxide (CO2) insufflation of the abdominal cavity to an intraabdominal pressure (IAP) of 12 to 15 mm Hg (Normal values are 5-7 mmHg) it is aimed to monitor optic sheat nerve diameter and lung ultrasound score changes with different intraabdominal pressures.
OTHERdesufflationLaparoscopic surgery begins with intraabdominal placement of the insufflation needle or trochar, followed by carbon dioxide (CO2) insufflation of the abdominal cavity to an intraabdominal pressure (IAP) of 12 to 15 mm Hg. When the surgery is completed, the trochars are removed and intra-abdominal pressure is returned to normal which is 5-7 mmHg.

Timeline

Start date
2024-01-15
Primary completion
2024-06-15
Completion
2024-06-15
First posted
2024-01-25
Last updated
2024-01-25

Source: ClinicalTrials.gov record NCT06224868. Inclusion in this directory is not an endorsement.